1065729 is a Phoenix Contact circuit breaker with Rated current Ie max. 40 A (IN+); Tripping characteristic B / C / D (EN 60934 / UL 1077); Number of poles 1 / 2 / 3 / 4 (EN 60934 / UL 1077). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Iemax. 40 A (IN+)
-
Tripping characteristicB / C / D (EN 60934 / UL 1077)
-
Number of poles1 / 2 / 3 / 4 (EN 60934 / UL 1077)
-
Breaking capacity Icu/Ics6 kA / 10 kA (EN 60934 / UL 1077)
Specifications
| Electrical |
| Rated current Ie |
max. 40 A (IN+) |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (EN 60934 / UL 1077) |
| Tripping characteristic |
B / C / D (EN 60934 / UL 1077) |
| Number of poles |
1 / 2 / 3 / 4 (EN 60934 / UL 1077) |
| Input voltage range |
7 V DC ... 30 V DC (Reset with falling edge) |
| Output current |
max. 0.04 A (Short-circuit-proof) |
| Efficiency |
> 99 % |
| I/O and communication |
| Sensing distance Sn |
8403361 h (at 25 °C with 21 % load) |
| Mechanical |
| Weight |
130 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 2.5 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
96 h, 95 % RH, 40 °C |
Values follow the Phoenix Contact circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact circuit breaker variants |
| Catalog number |
Rated operational voltage |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
1065729 (this page) |
— |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 1110984 |
12 V DC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 1115657 |
12 V DC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0712123 |
250 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1065729 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the max. 40 A (IN+) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1065729
Phoenix Contact 1065729 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 1065729; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Certifications: CE, UL, cULus — Record it with the other nameplate data when sourcing a replacement.
- Rated impulse withstand Uimp: 4 kV (IEC 60947-2) — Confirm the revision of the installed unit before a like-for-like replacement.
- Mounting: 35 mm DIN rail (IEC 60715) — Use it as the reference when cross-checking a current-production equivalent.
- Rated current Ie: max. 40 A (IN+) — Verify it in the project documentation before confirming the order.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about 1065729
Q.Where can I find the rated impulse withstand Uimp data for 1065729?
It is listed in the specification table for Phoenix Contact 1065729 as 4 kV (IEC 60947-2). Confirm this figure against the unit currently in the panel.
Q.For 1065729, what does the specification table state about certifications?
The specification table lists certifications = CE, UL, cULus for Phoenix Contact 1065729. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under breaking capacity Icu/Ics for catalog number 1065729?
For 1065729, breaking capacity Icu/Ics is given as 6 kA / 10 kA (EN 60934 / UL 1077). Check the revision of the installed unit if the catalog number has been superseded.
Q.What should I include in an enquiry for 1065729?
Send the full catalog number 1065729, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 1065729.
Q.How do I confirm compatibility of 1065729 before ordering?
Match the catalog number 1065729 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.