Phoenix Contact · DIN-rail power supply
1019979 is a Phoenix Contact circuit breaker with Rated current Ie 8 A; Tripping characteristic B / C / D (IEC 60947-2); Number of poles 1 / 2 / 3 / 4 (IEC 60947-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie8 A
-
Tripping characteristicB / C / D (IEC 60947-2)
-
Number of poles1 / 2 / 3 / 4 (IEC 60947-2)
-
Breaking capacity Icu/Ics6 kA / 10 kA (IEC 60947-2)
Specifications
| Electrical |
| Rated current Ie |
8 A |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (IEC 60947-2) |
| Tripping characteristic |
B / C / D (IEC 60947-2) |
| Number of poles |
1 / 2 / 3 / 4 (IEC 60947-2) |
| Rated torque |
2 Nm |
| Mechanical |
| Weight |
112.725 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
1 mm² ... 35 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
48 h, 95% RH, 40°C (IEC 60068-2-78) |
Values follow the Phoenix Contact DIN-rail power supply specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact DIN-rail power supply variants |
| Catalog number |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
1019979 (this page) |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1019976 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1019983 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1019990 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1019979 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the 8 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1019979
Phoenix Contact 1019979 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 1019979; record the nameplate data of the unit being replaced before selecting an equivalent.
- Breaking capacity Icu/Ics: 6 kA / 10 kA (IEC 60947-2) — Record it with the other nameplate data when sourcing a replacement.
- Number of poles: 1 / 2 / 3 / 4 (IEC 60947-2) — Confirm the revision of the installed unit before a like-for-like replacement.
- Certifications: CE, UL, cULus — Use it as the reference when cross-checking a current-production equivalent.
- Humidity: 48 h, 95% RH, 40°C (IEC 60068-2-78) — Verify it in the project documentation before confirming the order.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about 1019979
Q.For 1019979, what does the specification table state about mounting?
The specification table lists mounting = 35 mm DIN rail (IEC 60715) for Phoenix Contact 1019979. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under terminal wire size for catalog number 1019979?
For 1019979, terminal wire size is given as 1 mm² ... 35 mm². Check the revision of the installed unit if the catalog number has been superseded.
Q.Before ordering 1019979, which rated insulation voltage Ui entry should be checked?
The rated insulation voltage Ui entry quoted above is 440 V (IEC 60947-2). Compare it with the nameplate of the installed unit before ordering.
Q.How do I confirm compatibility of 1019979 before ordering?
Match the catalog number 1019979 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the 1019979 replace the unit currently installed in my panel?
Compare catalog number 1019979 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.