Phoenix Contact · circuit breaker
0916605 is a Phoenix Contact circuit breaker with Rated current Ie 2 A; Tripping characteristic B / C / D (EN 60934 / UL 1077); Number of poles 1 / 2 / 3 / 4 (EN 60934 / UL 1077). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie2 A
-
Tripping characteristicB / C / D (EN 60934 / UL 1077)
-
Number of poles1 / 2 / 3 / 4 (EN 60934 / UL 1077)
-
Rated operational voltage240 V AC (50/60 Hz)
Specifications
| Electrical |
| Rated current Ie |
2 A |
| Rated operational voltage |
240 V AC (50/60 Hz) |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (EN 60934 / UL 1077) |
| Tripping characteristic |
B / C / D (EN 60934 / UL 1077) |
| Number of poles |
1 / 2 / 3 / 4 (EN 60934 / UL 1077) |
| Rated torque |
1.5 ... 1.8 Nm |
| Mechanical |
| Weight |
63.475 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 10 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact circuit breaker variants |
| Catalog number |
Rated operational voltage |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
0916605 (this page) |
240 V AC (50/60 Hz) |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0916536 |
<= 440 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0911034 |
<= 440 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0914141 |
65 V DC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 0916605 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 240 V AC (50/60 Hz) — and switches or conditions the load within the 2 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 0916605
Phoenix Contact 0916605 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 0916605; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Mounting: 35 mm DIN rail (IEC 60715) — Record it with the other nameplate data when sourcing a replacement.
- Rated operational voltage: 240 V AC (50/60 Hz) — Confirm the revision of the installed unit before a like-for-like replacement.
- Terminal wire size: 0.2 mm² ... 10 mm² — Use it as the reference when cross-checking a current-production equivalent.
- Breaking capacity Icu/Ics: 6 kA / 10 kA (EN 60934 / UL 1077) — Verify it in the project documentation before confirming the order.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about 0916605
Q.Where can I find the rated current Ie data for 0916605?
It is listed in the specification table for Phoenix Contact 0916605 as 2 A. Use the value as the reference when sourcing a current-production equivalent.
Q.For 0916605, what does the specification table state about number of poles?
The specification table lists number of poles = 1 / 2 / 3 / 4 (EN 60934 / UL 1077) for Phoenix Contact 0916605. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under mounting for catalog number 0916605?
For 0916605, mounting is given as 35 mm DIN rail (IEC 60715). Compare it with the nameplate of the installed unit before ordering.
Q.What should I include in an enquiry for 0916605?
Send the full catalog number 0916605, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 0916605.
Q.How do I confirm compatibility of 0916605 before ordering?
Match the catalog number 0916605 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.