Phoenix Contact · circuit breaker
0911034 is a Phoenix Contact circuit breaker with Tripping characteristic B / C / D (EN 60934 / UL 1077); Number of poles 1 / 2 / 3 / 4 (EN 60934 / UL 1077); Rated operational voltage <= 440 V AC. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Tripping characteristicB / C / D (EN 60934 / UL 1077)
-
Number of poles1 / 2 / 3 / 4 (EN 60934 / UL 1077)
-
Rated operational voltage<= 440 V AC
-
Breaking capacity Icu/Ics6 kA / 10 kA (EN 60934 / UL 1077)
Specifications
| Electrical |
| Rated operational voltage |
<= 440 V AC |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (EN 60934 / UL 1077) |
| Tripping characteristic |
B / C / D (EN 60934 / UL 1077) |
| Number of poles |
1 / 2 / 3 / 4 (EN 60934 / UL 1077) |
| Mechanical |
| Weight |
73.44 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C |
| Certifications |
CE, UL, cULus |
| Humidity |
96 h, 95 % RH, 40 °C |
Values follow the Phoenix Contact circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact circuit breaker variants |
| Catalog number |
Rated operational voltage |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
0911034 (this page) |
<= 440 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0914141 |
65 V DC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0914400 |
250 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0914439 |
250 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 0911034 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — <= 440 V AC — and switches or conditions the load within the <= 440 V AC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 0911034
Phoenix Contact 0911034 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 0911034; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Rated operational voltage: <= 440 V AC — Verify it in the project documentation before confirming the order.
- Rated insulation voltage Ui: 440 V (IEC 60947-2) — Check this value against the nameplate of the installed unit before ordering.
- Humidity: 96 h, 95 % RH, 40 °C — Match it to the existing panel and upstream protection.
- Operating temperature: -25...+60 °C — Record it with the other nameplate data when sourcing a replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about 0911034
Q.Before ordering 0911034, which operating temperature entry should be checked?
The operating temperature entry quoted above is -25...+60 °C. Compare it with the nameplate of the installed unit before ordering.
Q.Where can I find the certifications data for 0911034?
It is listed in the specification table for Phoenix Contact 0911034 as CE, UL, cULus. Confirm this figure against the unit currently in the panel.
Q.For 0911034, what does the specification table state about rated operational voltage?
The specification table lists rated operational voltage = <= 440 V AC for Phoenix Contact 0911034. Use the value as the reference when sourcing a current-production equivalent.
Q.Can the 0911034 replace the unit currently installed in my panel?
Compare catalog number 0911034 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for 0911034?
Send the full catalog number 0911034, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 0911034.