Phoenix Contact · DIN-rail power supply
1020061 is a Phoenix Contact circuit breaker with Rated current Ie 2 A; Tripping characteristic B / C / D (IEC 60947-2); Number of poles 1 / 2 / 3 / 4 (IEC 60947-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie2 A
-
Tripping characteristicB / C / D (IEC 60947-2)
-
Number of poles1 / 2 / 3 / 4 (IEC 60947-2)
-
Breaking capacity Icu/Ics6 kA / 10 kA (IEC 60947-2)
Specifications
| Electrical |
| Rated current Ie |
2 A |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (IEC 60947-2) |
| Tripping characteristic |
B / C / D (IEC 60947-2) |
| Number of poles |
1 / 2 / 3 / 4 (IEC 60947-2) |
| Rated torque |
2 Nm |
| Mechanical |
| Weight |
226 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
1 mm² ... 35 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
48 h, 95% RH, 40°C (IEC 60068-2-78) |
Values follow the Phoenix Contact DIN-rail power supply specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact DIN-rail power supply variants |
| Catalog number |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
1020061 (this page) |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1010288 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1010308 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1018294 |
U/I |
yes |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1020061 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the 2 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1020061
Phoenix Contact 1020061 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 1020061; verify the catalog number against your bill of materials before requesting a quotation.
- Breaking capacity Icu/Ics: 6 kA / 10 kA (IEC 60947-2) — Verify it in the project documentation before confirming the order.
- Rated insulation voltage Ui: 440 V (IEC 60947-2) — Check this value against the nameplate of the installed unit before ordering.
- Rated torque: 2 Nm — Match it to the existing panel and upstream protection.
- Rated current Ie: 2 A — Record it with the other nameplate data when sourcing a replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about 1020061
Q.Before ordering 1020061, which certifications entry should be checked?
The certifications entry quoted above is CE, UL, cULus. Compare it with the nameplate of the installed unit before ordering.
Q.Where can I find the tripping characteristic data for 1020061?
It is listed in the specification table for Phoenix Contact 1020061 as B / C / D (IEC 60947-2). Confirm this figure against the unit currently in the panel.
Q.For 1020061, what does the specification table state about rated insulation voltage Ui?
The specification table lists rated insulation voltage Ui = 440 V (IEC 60947-2) for Phoenix Contact 1020061. Use the value as the reference when sourcing a current-production equivalent.
Q.How do I confirm compatibility of 1020061 before ordering?
Match the catalog number 1020061 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the 1020061 replace the unit currently installed in my panel?
Compare catalog number 1020061 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.