Phoenix Contact · circuit breaker
0914549 is a Phoenix Contact circuit breaker with Rated current Ie 16 A; Tripping characteristic B / C / D (EN 60934 / UL 1077); Number of poles 1 / 2 / 3 / 4 (EN 60934 / UL 1077). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie16 A
-
Tripping characteristicB / C / D (EN 60934 / UL 1077)
-
Number of poles1 / 2 / 3 / 4 (EN 60934 / UL 1077)
-
Rated operational voltage250 V AC
Specifications
| Electrical |
| Rated current Ie |
16 A |
| Rated operational voltage |
250 V AC |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (EN 60934 / UL 1077) |
| Tripping characteristic |
B / C / D (EN 60934 / UL 1077) |
| Number of poles |
1 / 2 / 3 / 4 (EN 60934 / UL 1077) |
| Rated torque |
0.6 ... 0.8 Nm |
| Mechanical |
| Weight |
62.25 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 6 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
240 h, 95 % RH, 40 °C |
Values follow the Phoenix Contact circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact circuit breaker variants |
| Catalog number |
Rated operational voltage |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
0914549 (this page) |
250 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0914507 |
250 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0914523 |
250 V AC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
| 0914141 |
65 V DC |
B / C / D (EN 60934 / UL 1077) |
6 kA / 10 kA (EN 60934 / UL 1077) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 0914549 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 250 V AC — and switches or conditions the load within the 16 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 0914549
Phoenix Contact 0914549 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 0914549; record the nameplate data of the unit being replaced before selecting an equivalent.
- Terminal wire size: 0.2 mm² ... 6 mm² — Use it as the reference when cross-checking a current-production equivalent.
- Rated insulation voltage Ui: 440 V (IEC 60947-2) — Verify it in the project documentation before confirming the order.
- Number of poles: 1 / 2 / 3 / 4 (EN 60934 / UL 1077) — Check this value against the nameplate of the installed unit before ordering.
- Rated operational voltage: 250 V AC — Match it to the existing panel and upstream protection.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about 0914549
Q.Which value is published under certifications for catalog number 0914549?
For 0914549, certifications is given as CE, UL, cULus. Compare it with the nameplate of the installed unit before ordering.
Q.Before ordering 0914549, which rated insulation voltage Ui entry should be checked?
The rated insulation voltage Ui entry quoted above is 440 V (IEC 60947-2). Confirm this figure against the unit currently in the panel.
Q.Where can I find the breaking capacity Icu/Ics data for 0914549?
It is listed in the specification table for Phoenix Contact 0914549 as 6 kA / 10 kA (EN 60934 / UL 1077). Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for 0914549?
Send the full catalog number 0914549, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 0914549.
Q.How do I confirm compatibility of 0914549 before ordering?
Match the catalog number 0914549 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.