Phoenix Contact · circuit breaker
0914523 is a Phoenix Contact circuit breaker with Rated current Ie 10 A; Tripping characteristic B / C / D (IEC 60947-2); Number of poles 1 / 2 / 3 / 4 (IEC 60947-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie10 A
-
Tripping characteristicB / C / D (IEC 60947-2)
-
Number of poles1 / 2 / 3 / 4 (IEC 60947-2)
-
Rated operational voltage250 V AC
Specifications
| Electrical |
| Rated current Ie |
10 A |
| Rated operational voltage |
250 V AC |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (IEC 60947-2) |
| Tripping characteristic |
B / C / D (IEC 60947-2) |
| Number of poles |
1 / 2 / 3 / 4 (IEC 60947-2) |
| Rated torque |
0.6 ... 0.8 Nm |
| Mechanical |
| Weight |
62.7 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 6 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
240 h, 95 % RH, 40 °C |
Values follow the Phoenix Contact circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact circuit breaker variants |
| Catalog number |
Rated operational voltage |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
0914523 (this page) |
250 V AC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 0914507 |
250 V AC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 0914549 |
250 V AC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 0914141 |
65 V DC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 0914523 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 250 V AC — and switches or conditions the load within the 10 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 0914523
Phoenix Contact 0914523 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 0914523; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Enclosure rating: IP20 (IEC 60529) — Use it as the reference when cross-checking a current-production equivalent.
- Rated current Ie: 10 A — Verify it in the project documentation before confirming the order.
- Rated insulation voltage Ui: 440 V (IEC 60947-2) — Check this value against the nameplate of the installed unit before ordering.
- Operating temperature: -25...+60 °C (IEC 60068-2-1) — Match it to the existing panel and upstream protection.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about 0914523
Q.Where can I find the humidity data for 0914523?
It is listed in the specification table for Phoenix Contact 0914523 as 240 h, 95 % RH, 40 °C. Compare it with the nameplate of the installed unit before ordering.
Q.For 0914523, what does the specification table state about rated current Ie?
The specification table lists rated current Ie = 10 A for Phoenix Contact 0914523. Confirm this figure against the unit currently in the panel.
Q.Which value is published under rated operational voltage for catalog number 0914523?
For 0914523, rated operational voltage is given as 250 V AC. Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for 0914523?
Send the full catalog number 0914523, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 0914523.
Q.How do I confirm compatibility of 0914523 before ordering?
Match the catalog number 0914523 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.