Phoenix Contact · DIN-rail power supply
1010308 is a Phoenix Contact circuit breaker with Rated current Ie 40 A; Tripping characteristic B / C / D (IEC 60947-2); Number of poles 1 / 2 / 3 / 4 (IEC 60947-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie40 A
-
Tripping characteristicB / C / D (IEC 60947-2)
-
Number of poles1 / 2 / 3 / 4 (IEC 60947-2)
-
Breaking capacity Icu/Ics6 kA / 10 kA (IEC 60947-2)
Specifications
| Electrical |
| Rated current Ie |
40 A |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (IEC 60947-2) |
| Tripping characteristic |
B / C / D (IEC 60947-2) |
| Number of poles |
1 / 2 / 3 / 4 (IEC 60947-2) |
| Rated torque |
2 Nm |
| Mechanical |
| Weight |
393 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
1 mm² ... 35 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
48 h, 95% RH, 40°C (IEC 60068-2-78) |
Values follow the Phoenix Contact DIN-rail power supply specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact DIN-rail power supply variants |
| Catalog number |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
1010308 (this page) |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1010288 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 1018294 |
U/I |
yes |
| 1019976 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1010308 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the 40 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1010308
Phoenix Contact 1010308 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 1010308; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Rated impulse withstand Uimp: 4 kV (IEC 60947-2) — Verify it in the project documentation before confirming the order.
- Mounting: 35 mm DIN rail (IEC 60715) — Check this value against the nameplate of the installed unit before ordering.
- Number of poles: 1 / 2 / 3 / 4 (IEC 60947-2) — Match it to the existing panel and upstream protection.
- Rated torque: 2 Nm — Record it with the other nameplate data when sourcing a replacement.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about 1010308
Q.For 1010308, what does the specification table state about humidity?
The specification table lists humidity = 48 h, 95% RH, 40°C (IEC 60068-2-78) for Phoenix Contact 1010308. Compare it with the nameplate of the installed unit before ordering.
Q.Which value is published under rated current Ie for catalog number 1010308?
For 1010308, rated current Ie is given as 40 A. Confirm this figure against the unit currently in the panel.
Q.Before ordering 1010308, which tripping characteristic entry should be checked?
The tripping characteristic entry quoted above is B / C / D (IEC 60947-2). Use the value as the reference when sourcing a current-production equivalent.
Q.Can the 1010308 replace the unit currently installed in my panel?
Compare catalog number 1010308 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of 1010308 before ordering?
Match the catalog number 1010308 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.