Phoenix Contact · circuit breaker
0712152 is a Phoenix Contact circuit breaker with Rated current Ie 0.5 A; Tripping characteristic B / C / D (IEC 60947-2); Number of poles 1 / 2 / 3 / 4 (IEC 60947-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie0.5 A
-
Tripping characteristicB / C / D (IEC 60947-2)
-
Number of poles1 / 2 / 3 / 4 (IEC 60947-2)
-
Rated operational voltage250 V AC
Specifications
| Electrical |
| Rated current Ie |
0.5 A |
| Rated operational voltage |
250 V AC |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (IEC 60947-2) |
| Tripping characteristic |
B / C / D (IEC 60947-2) |
| Number of poles |
1 / 2 / 3 / 4 (IEC 60947-2) |
| Mechanical |
| Weight |
11.35 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
240 h, 95 % RH, 40 °C |
Values follow the Phoenix Contact circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact circuit breaker variants |
| Catalog number |
Rated operational voltage |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
0712152 (this page) |
250 V AC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 0712123 |
250 V AC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 0911034 |
<= 440 V AC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 0914141 |
65 V DC |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 0712152 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 250 V AC — and switches or conditions the load within the 0.5 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 0712152
Phoenix Contact 0712152 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 0712152; record the nameplate data of the unit being replaced before selecting an equivalent.
- Breaking capacity Icu/Ics: 6 kA / 10 kA (IEC 60947-2) — Check this value against the nameplate of the installed unit before ordering.
- Humidity: 240 h, 95 % RH, 40 °C — Match it to the existing panel and upstream protection.
- Weight: 11.35 g — Record it with the other nameplate data when sourcing a replacement.
- Rated impulse withstand Uimp: 4 kV (IEC 60947-2) — Confirm the revision of the installed unit before a like-for-like replacement.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about 0712152
Q.For 0712152, what does the specification table state about number of poles?
The specification table lists number of poles = 1 / 2 / 3 / 4 (IEC 60947-2) for Phoenix Contact 0712152. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under certifications for catalog number 0712152?
For 0712152, certifications is given as CE, UL, cULus. Compare it with the nameplate of the installed unit before ordering.
Q.Before ordering 0712152, which weight entry should be checked?
The weight entry quoted above is 11.35 g. Confirm this figure against the unit currently in the panel.
Q.Can the 0712152 replace the unit currently installed in my panel?
Compare catalog number 0712152 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of 0712152 before ordering?
Match the catalog number 0712152 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.