Phoenix Contact · contactor
1032927 is a Phoenix Contact contactor with Enclosure rating IP20 (IEC 60529); Mounting 35 mm DIN rail (IEC 60715); Operating temperature -25...+60 °C (IEC 60068-2-1). It is used in motor starters, pump control panels, HVAC contactor banks where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Enclosure ratingIP20 (IEC 60529)
-
Mounting35 mm DIN rail (IEC 60715)
-
Operating temperature-25...+60 °C (IEC 60068-2-1)
-
CertificationsCE, UL, cULus
Specifications
| Electrical |
| Rated insulation voltage Ui |
690 V (IEC 60947-4-1) |
| Rated impulse withstand Uimp |
6 kV (IEC 60947-4-1) |
| Tripping characteristic |
8 mm |
| Frequency |
6 Hz |
| Rated torque |
0.5 Nm ... 0.6 Nm |
| Mechanical |
| Weight |
519.6 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.5 mm² ... 2.5 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact contactor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact contactor variants |
| Catalog number |
Mounting |
|
1032927 (this page) |
35 mm DIN rail (IEC 60715) |
| 1032921 |
35 mm DIN rail (IEC 60715) |
| 1032926 |
35 mm DIN rail (IEC 60715) |
| 1032919 |
35 mm DIN rail (IEC 60715) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1032927 is the device-level element in a Phoenix Contact contactor installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in motor starters, pump control panels, HVAC contactor banks, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1032927
Phoenix Contact 1032927 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 1032927; record the nameplate data of the unit being replaced before selecting an equivalent.
- Rated impulse withstand Uimp: 6 kV (IEC 60947-4-1) — Confirm the revision of the installed unit before a like-for-like replacement.
- Operating temperature: -25...+60 °C (IEC 60068-2-1) — Use it as the reference when cross-checking a current-production equivalent.
- Certifications: CE, UL, cULus — Verify it in the project documentation before confirming the order.
- Rated insulation voltage Ui: 690 V (IEC 60947-4-1) — Check this value against the nameplate of the installed unit before ordering.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about 1032927
Q.Which value is published under weight for catalog number 1032927?
For 1032927, weight is given as 519.6 g. Use the value as the reference when sourcing a current-production equivalent.
Q.Before ordering 1032927, which mounting entry should be checked?
The mounting entry quoted above is 35 mm DIN rail (IEC 60715). Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the terminal wire size data for 1032927?
It is listed in the specification table for Phoenix Contact 1032927 as 0.5 mm² ... 2.5 mm². Compare it with the nameplate of the installed unit before ordering.
Q.How do I confirm compatibility of 1032927 before ordering?
Match the catalog number 1032927 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the 1032927 replace the unit currently installed in my panel?
Compare catalog number 1032927 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.