Phoenix Contact · HC-B
1648030 is a Phoenix Contact circuit breaker with Rated current Ie 16 A; Tripping characteristic 12 mm; Rated operational voltage 500 V. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie16 A
-
Tripping characteristic12 mm
-
Rated operational voltage500 V
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated current Ie |
16 A |
| Rated operational voltage |
500 V |
| Tripping characteristic |
12 mm |
| Rated torque |
0.5 Nm ... 0.8 Nm |
| Mechanical |
| Weight |
107.94 g |
| Mounting |
DIN rail / panel |
| Terminal wire size |
0.5 mm² ... 2.5 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact HC-B specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact HC-B variants |
| Catalog number |
Tripping characteristic |
Rated operational voltage |
|
1648030 (this page) |
12 mm |
500 V |
| 1648072 |
12 mm |
500 V |
| 1648090 |
12 mm |
500 V |
| 1605569 |
— |
500 V |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1648030 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 500 V — and switches or conditions the load within the 16 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1648030
Phoenix Contact 1648030 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 1648030; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Rated current Ie: 16 A — Verify it in the project documentation before confirming the order.
- Operating temperature: 0...+55 °C (IEC 60068-2-1) — Check this value against the nameplate of the installed unit before ordering.
- Rated torque: 0.5 Nm ... 0.8 Nm — Match it to the existing panel and upstream protection.
- Certifications: CE, UL, cULus — Record it with the other nameplate data when sourcing a replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about 1648030
Q.Which value is published under terminal wire size for catalog number 1648030?
For 1648030, terminal wire size is given as 0.5 mm² ... 2.5 mm². Check the revision of the installed unit if the catalog number has been superseded.
Q.Before ordering 1648030, which weight entry should be checked?
The weight entry quoted above is 107.94 g. Compare it with the nameplate of the installed unit before ordering.
Q.Where can I find the rated operational voltage data for 1648030?
It is listed in the specification table for Phoenix Contact 1648030 as 500 V. Confirm this figure against the unit currently in the panel.
Q.What should I include in an enquiry for 1648030?
Send the full catalog number 1648030, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 1648030.
Q.How do I confirm compatibility of 1648030 before ordering?
Match the catalog number 1648030 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.