SICK · Incremental / absolute encoder
AFM60B-TEKZ0-S01 is a SICK encoder with Supply voltage 10...30 V DC; Enclosure rating IP65 / IP67 (IEC 60529); Operating temperature -20...+70 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage10...30 V DC
-
Enclosure ratingIP65 / IP67 (IEC 60529)
-
Operating temperature-20...+70 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| I/O and communication |
| Resolution |
incremental or absolute, up to 65,536 ppr |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP65 / IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-20...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the SICK Incremental / absolute encoder specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The AFM60B-TEKZ0-S01 is the device-level element in a SICK encoder installation. It receives the field signals and control supply listed above — 10...30 V DC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for SICK AFM60B-TEKZ0
SICK AFM60B-TEKZ0 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number AFM60B-TEKZ0; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Supply voltage: 10...30 V DC — Check this value against the nameplate of the installed unit before ordering.
- Mounting: DIN rail / panel — Match it to the existing panel and upstream protection.
- Certifications: CE, cULus — Record it with the other nameplate data when sourcing a replacement.
- Resolution: incremental or absolute, up to 65,536 ppr — Confirm the revision of the installed unit before a like-for-like replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about AFM60B-TEKZ0
Q.Before ordering AFM60B-TEKZ0, which certifications entry should be checked?
The certifications entry quoted above is CE, cULus. Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the resolution data for AFM60B-TEKZ0?
It is listed in the specification table for SICK AFM60B-TEKZ0 as incremental or absolute, up to 65,536 ppr. Compare it with the nameplate of the installed unit before ordering.
Q.For AFM60B-TEKZ0, what does the specification table state about mounting?
The specification table lists mounting = DIN rail / panel for SICK AFM60B-TEKZ0. Confirm this figure against the unit currently in the panel.
Q.What should I include in an enquiry for AFM60B-TEKZ0?
Send the full catalog number AFM60B-TEKZ0, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for SICK AFM60B-TEKZ0.
Q.How do I confirm compatibility of AFM60B-TEKZ0 before ordering?
Match the catalog number AFM60B-TEKZ0 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.