SICK · Incremental / absolute encoder
AFM60B-TEAM008192 is a SICK encoder with Supply voltage 10...30 V DC; Enclosure rating IP65 / IP67 (IEC 60529); Operating temperature -20...+70 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage10...30 V DC
-
Enclosure ratingIP65 / IP67 (IEC 60529)
-
Operating temperature-20...+70 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| I/O and communication |
| Resolution |
incremental or absolute, up to 65,536 ppr |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP65 / IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-20...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the SICK Incremental / absolute encoder specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The AFM60B-TEAM008192 is the device-level element in a SICK encoder installation. It receives the field signals and control supply listed above — 10...30 V DC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for SICK AFM60B-TEAM008192
SICK AFM60B-TEAM008192 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number AFM60B-TEAM008192; record the nameplate data of the unit being replaced before selecting an equivalent.
- Enclosure rating: IP65 / IP67 (IEC 60529) — Use it as the reference when cross-checking a current-production equivalent.
- Operating temperature: -20...+70 °C (IEC 60068-2-1) — Verify it in the project documentation before confirming the order.
- Mounting: DIN rail / panel — Check this value against the nameplate of the installed unit before ordering.
- Supply voltage: 10...30 V DC — Match it to the existing panel and upstream protection.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about AFM60B-TEAM008192
Q.Where can I find the supply voltage data for AFM60B-TEAM008192?
It is listed in the specification table for SICK AFM60B-TEAM008192 as 10...30 V DC. Confirm this figure against the unit currently in the panel.
Q.For AFM60B-TEAM008192, what does the specification table state about resolution?
The specification table lists resolution = incremental or absolute, up to 65,536 ppr for SICK AFM60B-TEAM008192. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under enclosure rating for catalog number AFM60B-TEAM008192?
For AFM60B-TEAM008192, enclosure rating is given as IP65 / IP67 (IEC 60529). Check the revision of the installed unit if the catalog number has been superseded.
Q.Can the AFM60B-TEAM008192 replace the unit currently installed in my panel?
Compare catalog number AFM60B-TEAM008192 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of AFM60B-TEAM008192 before ordering?
Match the catalog number AFM60B-TEAM008192 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.