SICK · Incremental / absolute encoder
AFM60E-S1AL004096 is a SICK encoder with Supply voltage 10...30 V DC; Enclosure rating IP65 / IP67 (IEC 60529); Operating temperature -20...+70 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage10...30 V DC
-
Enclosure ratingIP65 / IP67 (IEC 60529)
-
Operating temperature-20...+70 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| I/O and communication |
| Resolution |
incremental or absolute, up to 65,536 ppr |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP65 / IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-20...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the SICK Incremental / absolute encoder specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The AFM60E-S1AL004096 is the device-level element in a SICK encoder installation. It receives the field signals and control supply listed above — 10...30 V DC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for SICK AFM60E-S1AL004096
SICK AFM60E-S1AL004096 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number AFM60E-S1AL004096; record the nameplate data of the unit being replaced before selecting an equivalent.
- Resolution: incremental or absolute, up to 65,536 ppr — Match it to the existing panel and upstream protection.
- Mounting: DIN rail / panel — Record it with the other nameplate data when sourcing a replacement.
- Enclosure rating: IP65 / IP67 (IEC 60529) — Confirm the revision of the installed unit before a like-for-like replacement.
- Supply voltage: 10...30 V DC — Use it as the reference when cross-checking a current-production equivalent.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about AFM60E-S1AL004096
Q.Before ordering AFM60E-S1AL004096, which supply voltage entry should be checked?
The supply voltage entry quoted above is 10...30 V DC. Confirm this figure against the unit currently in the panel.
Q.Where can I find the mounting data for AFM60E-S1AL004096?
It is listed in the specification table for SICK AFM60E-S1AL004096 as DIN rail / panel. Use the value as the reference when sourcing a current-production equivalent.
Q.For AFM60E-S1AL004096, what does the specification table state about certifications?
The specification table lists certifications = CE, cULus for SICK AFM60E-S1AL004096. Check the revision of the installed unit if the catalog number has been superseded.
Q.How do I confirm compatibility of AFM60E-S1AL004096 before ordering?
Match the catalog number AFM60E-S1AL004096 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.What should I include in an enquiry for AFM60E-S1AL004096?
Send the full catalog number AFM60E-S1AL004096, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for SICK AFM60E-S1AL004096.