Phoenix Contact · Contactron motor starter
2908672 is a Phoenix Contact circuit breaker with Tripping characteristic B / C / D (IEC 60947-2); Number of poles 1 / 2 / 3 / 4 (IEC 60947-2); Breaking capacity Icu/Ics 6 kA / 10 kA (IEC 60947-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Tripping characteristicB / C / D (IEC 60947-2)
-
Number of poles1 / 2 / 3 / 4 (IEC 60947-2)
-
Breaking capacity Icu/Ics6 kA / 10 kA (IEC 60947-2)
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated insulation voltage Ui |
440 V (IEC 60947-2) |
| Rated impulse withstand Uimp |
4 kV (IEC 60947-2) |
| Breaking capacity Icu/Ics |
6 kA / 10 kA (IEC 60947-2) |
| Tripping characteristic |
B / C / D (IEC 60947-2) |
| Number of poles |
1 / 2 / 3 / 4 (IEC 60947-2) |
| Frequency |
≤ 2 Hz (Load-dependent) |
| Mechanical |
| Weight |
299.366 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 2.5 mm² |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact Contactron motor starter specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Contactron motor starter variants |
| Catalog number |
Tripping characteristic |
Breaking capacity Icu/Ics |
|
2908672 (this page) |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 2908669 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
| 2900017 |
8 mm |
— |
| 2900414 |
B / C / D (IEC 60947-2) |
6 kA / 10 kA (IEC 60947-2) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 2908672 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 2908672
Phoenix Contact 2908672 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 2908672; verify the catalog number against your bill of materials before requesting a quotation.
- Enclosure rating: IP20 (IEC 60529) — Use it as the reference when cross-checking a current-production equivalent.
- Frequency: ≤ 2 Hz (Load-dependent) — Verify it in the project documentation before confirming the order.
- Terminal wire size: 0.2 mm² ... 2.5 mm² — Check this value against the nameplate of the installed unit before ordering.
- Breaking capacity Icu/Ics: 6 kA / 10 kA (IEC 60947-2) — Match it to the existing panel and upstream protection.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about 2908672
Q.Where can I find the number of poles data for 2908672?
It is listed in the specification table for Phoenix Contact 2908672 as 1 / 2 / 3 / 4 (IEC 60947-2). Compare it with the nameplate of the installed unit before ordering.
Q.For 2908672, what does the specification table state about frequency?
The specification table lists frequency = ≤ 2 Hz (Load-dependent) for Phoenix Contact 2908672. Confirm this figure against the unit currently in the panel.
Q.Which value is published under tripping characteristic for catalog number 2908672?
For 2908672, tripping characteristic is given as B / C / D (IEC 60947-2). Use the value as the reference when sourcing a current-production equivalent.
Q.Can the 2908672 replace the unit currently installed in my panel?
Compare catalog number 2908672 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of 2908672 before ordering?
Match the catalog number 2908672 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.