Phoenix Contact · Power Distributor
1692433 is a Phoenix Contact circuit breaker with Rated current Ie 12 A; Rated operational voltage <= 440 V AC; Breaking capacity Icu/Ics Supply voltage Green LED. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie12 A
-
Rated operational voltage<= 440 V AC
-
Breaking capacity Icu/IcsSupply voltage Green LED
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated current Ie |
12 A |
| Rated operational voltage |
<= 440 V AC |
| Breaking capacity Icu/Ics |
Supply voltage Green LED |
| Input voltage range |
85...264 V AC / 110...300 V DC (IEC 61010) |
| Efficiency |
up to 94 % |
| Rated torque |
0.4 Nm |
| Mechanical |
| Weight |
133.8 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact Power Distributor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Power Distributor variants |
| Catalog number |
Breaking capacity Icu/Ics |
Rated operational voltage |
|
1692433 (this page) |
Supply voltage Green LED |
<= 440 V AC |
| 1692404 |
Supply voltage Green LED |
<= 440 V AC |
| 1692459 |
Supply voltage Green LED |
<= 440 V AC |
| 1692501 |
Supply voltage Green LED |
<= 440 V AC |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1692433 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — <= 440 V AC — and switches or conditions the load within the 12 A ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1692433
Phoenix Contact 1692433 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 1692433; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Rated torque: 0.4 Nm — Check this value against the nameplate of the installed unit before ordering.
- Efficiency: up to 94 % — Match it to the existing panel and upstream protection.
- Certifications: CE, UL, cULus — Record it with the other nameplate data when sourcing a replacement.
- Input voltage range: 85...264 V AC / 110...300 V DC (IEC 61010) — Confirm the revision of the installed unit before a like-for-like replacement.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about 1692433
Q.Where can I find the rated operational voltage data for 1692433?
It is listed in the specification table for Phoenix Contact 1692433 as <= 440 V AC. Confirm this figure against the unit currently in the panel.
Q.For 1692433, what does the specification table state about operating temperature?
The specification table lists operating temperature = -25...+60 °C for Phoenix Contact 1692433. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under rated current Ie for catalog number 1692433?
For 1692433, rated current Ie is given as 12 A. Check the revision of the installed unit if the catalog number has been superseded.
Q.Can the 1692433 replace the unit currently installed in my panel?
Compare catalog number 1692433 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for 1692433?
Send the full catalog number 1692433, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 1692433.