Phoenix Contact · Fiber Optic Distributor
1208054 is a Phoenix Contact industrial component with Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1); Mounting DIN rail / panel. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
-
CertificationsCE, UL, cULus
Specifications
| Mechanical |
| Weight |
548.6 g |
| Mounting |
DIN rail / panel |
| Terminal wire size |
4 |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact Fiber Optic Distributor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Fiber Optic Distributor variants |
| Catalog number |
Mounting |
|
1208054 (this page) |
DIN rail / panel |
| 1208051 |
DIN rail / panel |
| 1208052 |
DIN rail / panel |
| 1208432 |
DIN rail / panel |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1208054 is the device-level element in a Phoenix Contact industrial component installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1208054
Phoenix Contact 1208054 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 1208054; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Enclosure rating: IP20 (IEC 60529) — Check this value against the nameplate of the installed unit before ordering.
- Mounting: DIN rail / panel — Match it to the existing panel and upstream protection.
- Operating temperature: 0...+55 °C (IEC 60068-2-1) — Record it with the other nameplate data when sourcing a replacement.
- Certifications: CE, UL, cULus — Confirm the revision of the installed unit before a like-for-like replacement.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about 1208054
Q.Where can I find the weight data for 1208054?
It is listed in the specification table for Phoenix Contact 1208054 as 548.6 g. Check the revision of the installed unit if the catalog number has been superseded.
Q.For 1208054, what does the specification table state about operating temperature?
The specification table lists operating temperature = 0...+55 °C (IEC 60068-2-1) for Phoenix Contact 1208054. Compare it with the nameplate of the installed unit before ordering.
Q.Which value is published under enclosure rating for catalog number 1208054?
For 1208054, enclosure rating is given as IP20 (IEC 60529). Confirm this figure against the unit currently in the panel.
Q.What should I include in an enquiry for 1208054?
Send the full catalog number 1208054, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 1208054.
Q.How do I confirm compatibility of 1208054 before ordering?
Match the catalog number 1208054 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.