Beckhoff · EtherCAT Terminal
EL3314-0010 is a Beckhoff industrial component with Supply voltage 24 V DC (IEC 61131-2); Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Tripping characteristic |
8…9 mm |
| Supply voltage |
24 V DC (IEC 61131-2) |
| Frequency |
typ. 1 kHz |
| I/O and communication |
| Bus interface |
typ. 200 mA |
| Communication ports |
EtherCAT, Ethernet |
| Resolution |
24 bit, presentation adjustable: 0.1/0.01/0.001°C per digit or 10 nV per digit |
| Mechanical |
| Dimensions (H x W x D) |
12 mm x 100 mm x 68 mm |
| Weight |
approx. 60 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Storage temperature |
-40…+85°C |
| Certifications |
CE, UL, cULus |
| Humidity |
95%, no condensation |
Values follow the Beckhoff EtherCAT Terminal specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Beckhoff EtherCAT Terminal variants |
| Catalog number |
Mounting |
|
EL3314-0010 (this page) |
35 mm DIN rail (IEC 60715) |
| EL3314-0090 |
35 mm DIN rail (IEC 60715) |
| EL3314 |
35 mm DIN rail (IEC 60715) |
| EL3312 |
35 mm DIN rail (IEC 60715) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The EL3314-0010 is the device-level element in a Beckhoff industrial component installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Beckhoff EL3314-0010
Beckhoff EL3314-0010 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number EL3314-0010; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Weight: approx. 60 g — Verify it in the project documentation before confirming the order.
- Mounting: 35 mm DIN rail (IEC 60715) — Check this value against the nameplate of the installed unit before ordering.
- Communication ports: EtherCAT, Ethernet — Match it to the existing panel and upstream protection.
- Dimensions (H x W x D): 12 mm x 100 mm x 68 mm — Record it with the other nameplate data when sourcing a replacement.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about EL3314-0010
Q.Where can I find the storage temperature data for EL3314-0010?
It is listed in the specification table for Beckhoff EL3314-0010 as -40…+85°C. Confirm this figure against the unit currently in the panel.
Q.For EL3314-0010, what does the specification table state about certifications?
The specification table lists certifications = CE, UL, cULus for Beckhoff EL3314-0010. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under operating temperature for catalog number EL3314-0010?
For EL3314-0010, operating temperature is given as 0...+55 °C (IEC 60068-2-1). Check the revision of the installed unit if the catalog number has been superseded.
Q.How do I confirm compatibility of EL3314-0010 before ordering?
Match the catalog number EL3314-0010 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the EL3314-0010 replace the unit currently installed in my panel?
Compare catalog number EL3314-0010 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.