Beckhoff · EtherCAT Terminal

EL2819 is a Beckhoff circuit breaker with Tripping characteristic 8…9 mm; Rated operational voltage 24 V DC (-15%/+20%); Breaking capacity Icu/Ics typ. < 1 A. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Tripping characteristic8…9 mm
  • Rated operational voltage24 V DC (-15%/+20%)
  • Breaking capacity Icu/Icstyp. &lt; 1 A
  • Supply voltage24 V DC (IEC 61131-2)

Specifications

Electrical
Rated operational voltage 24 V DC (-15%/+20%)
Breaking capacity Icu/Ics typ. &lt; 1 A
Tripping characteristic 8…9 mm
Supply voltage 24 V DC (IEC 61131-2)
Output current 0.5 A (short-circuit proof) per channel
I/O and communication
Bus interface typ. 90 mA
Communication ports EtherCAT, Ethernet
Output stage push (high-side switch)
Mechanical
Dimensions (H x W x D) 12 mm x 100 mm x 68 mm
Weight approx. 70 g
Mounting 35 mm DIN rail (IEC 60715)
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature 0...+55 °C (IEC 60068-2-1)
Storage temperature -40…+85°C
Certifications CE, UL, cULus
Humidity 95%, no condensation

Values follow the Beckhoff EtherCAT Terminal specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

Beckhoff EtherCAT Terminal variants
Catalog number Breaking capacity Icu/Ics Tripping characteristic Rated operational voltage
EL2819 (this page) typ. &lt; 1 A 8…9 mm 24 V DC (-15%/+20%)
EL2808 typ. &lt; 2 A 8…9 mm 24 V DC (-15%/+20%)
EL2809 typ. &lt; 2 A 8…9 mm 24 V DC (-15%/+20%)
EL2828 typ. &lt; 40 A 8…9 mm 24 V DC (-15%/+20%)

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The EL2819 is the device-level element in a Beckhoff circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the 24 V DC (-15%/+20%) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for Beckhoff EL2819

Beckhoff EL2819 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number EL2819; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.

  • Output current: 0.5 A (short-circuit proof) per channel — Match it to the existing panel and upstream protection.
  • Operating temperature: 0...+55 °C (IEC 60068-2-1) — Record it with the other nameplate data when sourcing a replacement.
  • Supply voltage: 24 V DC (IEC 61131-2) — Confirm the revision of the installed unit before a like-for-like replacement.
  • Storage temperature: -40…+85°C — Use it as the reference when cross-checking a current-production equivalent.

For a discontinued unit, match function and electrical ratings rather than the label alone.

Common questions about EL2819

Q.Which value is published under weight for catalog number EL2819?

For EL2819, weight is given as approx. 70 g. Use the value as the reference when sourcing a current-production equivalent.

Q.Before ordering EL2819, which storage temperature entry should be checked?

The storage temperature entry quoted above is -40…+85°C. Check the revision of the installed unit if the catalog number has been superseded.

Q.Where can I find the rated operational voltage data for EL2819?

It is listed in the specification table for Beckhoff EL2819 as 24 V DC (-15%/+20%). Compare it with the nameplate of the installed unit before ordering.

Q.What should I include in an enquiry for EL2819?

Send the full catalog number EL2819, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Beckhoff EL2819.

Q.How do I confirm compatibility of EL2819 before ordering?

Match the catalog number EL2819 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!