| Electrical |
| Number Of Channels |
1 |
| Power Supply |
1.2A @ 5.1V DC & 3mA @ 24V DC dc |
| Current draw @ 24V DC |
3 mA |
| Current draw @ 5.1V DC |
1200 mA |
| Power dissipation |
6.2 W |
| Power supply, redundant |
1756-PA1756-PA75R, 1756-PB75R, 1756-PSCA2 |
| Power supply, standard |
1756-PA72/C, 1756-PA75/B, 1756-PB72/C, 1756-PB75/B, 1756-PC75/B, 1756-PH75/B |
| Removal and Insertion Under Power |
1-6 |
| Backplane connector |
The backplane connector connects the ; module to the ControlLogix chassis ; backplane. |
| Mechanical |
| Slot width |
1 |
| Enclosure type rating |
None (open-style) |
| Environment and compliance |
| Environmental Compliance |
See Details | Submit Inquiry |
| Vibration |
2 g @ 10…500 Hz |
| Temperature, storage |
-40…85 °C (-40…185 °F) |
| Temperature, operating |
0…60 °C (32…140 °F) |
| Shock, operating |
30 g |
| Shock, nonoperating |
50 g |
| Relative humidity |
5…95% noncondensing |
| Radiated RF immunity |
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz / 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz / 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz |
| Emissions / CISPR 11 (IEC 61000-6-4) |
Class A |
| ESD immunity |
6 kV contact discharges / 8 kV air discharges |
| Temperature, surrounding air, max. |
60 °C (140 °F) |
| General |
| Communication |
SynchLink |
| LCA Method |
ISO 14040/44 compliant |
| Impact Assessment Method |
EF 3.0 (Environmental Footprint) ESPR aligned |
| Database Used |
Ecoinvent 3.10 |
| Use Phase Electricity |
European Average Grid Mix (EU-40) |
| Cradle To Grave |
311 kg CO2 eq |
| Cradle To Gate |
43.8 kg CO2 eq |
| SVHC Information |
View Guidance |
| Chassis |
1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17 |
| Frame parameters |
3 Flags - 3 bytes / Control field - 1 byte / Data field - 24 bytes / CRC field - 2 bytes |
| Frame period |
μs / 50 |
| Module location |
Chassis-based, any slot |
| Operating wavelength |
650 nm (red) |
| SynchLink data rate |
5 Mbps |
| Thermal dissipation |
21.2 BTU/hr |
| Type of communication |
Synchronous |
| Cable fiber termination type |
Versalink V-System |
| Cable fiber type |
200/230 micron HCS (Hard Clad Silica) |
| Cable length |
1…300 m (3.28…984.2 ft) |
| North American Temp Code |
T4A |
| Ports |
2 fiber optic |
| 1403-CFxxx |
Rockwell Automation fiber-optic cable assembly |
| CSA |
CSA Certified Process Control Equipment. See CSA File LR54689C / CSA Certified Process Control Equipment for Class I, Division 2 Group A,B,C,D Hazardous Locations. See CSA file LR69960C |
| FM |
FM Approved Equipment for use in Class I Division 2 Group A,B,C,D Hazardous Locations |
| HCP-M0200T V01RK |
μm ; Lucent Technologies 200 simplex cable |
| UL |
UL Listed Industrial Control Equipment. See UL file E65584 |
| ControlLogix System |
Time Synchronization in a Distributed Control System . . . . . . . . . . 2-2 |
| SynchLink Module Features |
Module Features That Cannot Be Configured . . . . . . . . . . . . . . . . . . 3-2 |
| Time Synchronization in the |
Using the Coordinated System Time (CST) . . . . . . . . . . . . . . . . . . . . 2-2 |
| Connecting a SynchLink Module to a SynchLink System |
1-3 |
| For information on: |
See page: |
| Preventing Electrostatic Discharge |
1-6 |
| Using Module Identification and Status Information |
1-5 |
| What is the ControlLogix SynchLink Module? |
1-1 |
| Physical Feature: |
Description: |
| Receive fiber port |
The receive fiber port allows connection (via ; fiber optic cables) to other SynchLink ; modules so the module can receive data. |
| Transmit fiber port |
The transmit fiber port allows connection ; (via fiber optic cables) to other SynchLink ; modules so the module can send data. |
| ASCII Text String |
Module name |
| Length of ASCII Text String |
Number of characters in module’s text string |
| Major Revision |
Module’s major revision number |
| Minor Revision |
Module’s minor revision number |
| Module Identification: |
Description: |
| Product Code |
Module’s catalog number |
| Product Type |
Module’s product type, such as Digital I/O or Analog I/O ; module |
| Serial Number |
Module serial number |
| Status |
Module’s status. Returns the following information: ; • ; Controller ownership (if any) ; • ; Whether module has been configured ; • ; Device Specific Status, such as: ; – Self-Test ; – Flash update in progress ; – Communications fault ; – Not owned (outputs in program mode) ; – Internal fault (need flash update) ; – Run mode ; • ; Minor recoverable fault ; • ; Minor unrecoverable fault ; • ; Major recoverable fault ; • ; Major unrecoverable fault |
| Vendor ID |
Module manufacturer vendor, for example Allen-Bradley |
| How Do the CST Clock and SynchLink Node Clock Work Together? |
2-5 |
| Time Synchronization in a Distributed Control System |
2-2 |
| Time Synchronization in the SynchLink System |
2-2 |
| Using the Coordinated System Time (CST) |
2-2 |
| What are the SynchLink Configurations? |
2-6 |
| Name: |
Description: / Data Type / Attribute ID: / Possible Values: |
| Class |
31B / 31B |
| Field: |
Value to Retrieve the Counter: / Value to Reset the Counter: |
| Instance |
1 / 1 |
| Message Type |
CIP Generic / CIP Generic |
| Service Code |
1 / 5 |
| Local:x:C.ChassisCSTMst |
BOOL / If this bit is set to 1, the module becomes the CST master for its chassis. |
| Local:x:C.RemainChassisCSTMst |
BOOL / If this bit is set to 1, the module remains Chassis CST master for its chassis ; even if communications with the SynchLink CST master are lost. |
| Local:x:C.SLCSTMst |
BOOL / If this bit is set to 1, the module becomes the CST master for the entire ; SynchLink. |
| Local:x:C.TempChassisCSTMst |
BOOL / If this bit is set to 1, the module acts as Chassis CST master for its chassis ; and ignores the SynchLink CST master. |
| Name |
Type: / Definition: |
| Not published by the manufacturer — 待原厂规格书核定 |
| Supply voltage |
待原厂规格书核定 |
| Mounting |
待原厂规格书核定 |
| Enclosure rating |
待原厂规格书核定 |
| Operating temperature |
待原厂规格书核定 |
| Certifications |
待原厂规格书核定 |
Available from stock with datasheet, certificates and a quotation on request.