Phoenix Contact · Terminal Block
2744458 is a Phoenix Contact terminal block with Rated current Ie up to 41 A (IEC 60947-7-1); Rated operational voltage 800 V (IEC 60947-7-1); Supply voltage 19.2 V AC/DC ... 28.8 V AC/DC. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ieup to 41 A (IEC 60947-7-1)
-
Rated operational voltage800 V (IEC 60947-7-1)
-
Supply voltage19.2 V AC/DC ... 28.8 V AC/DC
-
Operating temperature0 °C ... 55 °C
Specifications
| Electrical |
| Rated current Ie |
up to 41 A (IEC 60947-7-1) |
| Rated operational voltage |
800 V (IEC 60947-7-1) |
| Supply voltage |
19.2 V AC/DC ... 28.8 V AC/DC |
| Output current |
2x 20 mA ±10 % (Loop current) |
| Frequency |
Test Level 3 |
| Rated torque |
0.56 Nm ... 0.79 Nm |
| Rated speed |
≤ 19.2 kbps |
| I/O and communication |
| Protocols |
transparent protocol |
| Mechanical |
| Weight |
184 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal type |
0.2 mm² ... 2.5 mm² |
| Terminal wire size |
13 |
| Environment and compliance |
| Operating temperature |
0 °C ... 55 °C |
| Certifications |
CE, UL, cULus |
| Humidity |
10 % ... 95 % (non-condensing) |
Values follow the Phoenix Contact Terminal Block specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Terminal Block variants |
| Catalog number |
Rated current Ie |
Rated operational voltage |
Mounting |
|
2744458 (this page) |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
| 2744416 |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
| 2744461 |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
| 2744490 |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 2744458 is the device-level element in a Phoenix Contact terminal block installation. It receives the field signals and control supply listed above — 19.2 V AC/DC ... 28.8 V AC/DC — and switches or conditions the load within the up to 41 A (IEC 60947-7-1) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 2744458
Phoenix Contact 2744458 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 2744458; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Frequency: Test Level 3 — Use it as the reference when cross-checking a current-production equivalent.
- Rated torque: 0.56 Nm ... 0.79 Nm — Verify it in the project documentation before confirming the order.
- Protocols: transparent protocol — Check this value against the nameplate of the installed unit before ordering.
- Operating temperature: 0 °C ... 55 °C — Match it to the existing panel and upstream protection.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about 2744458
Q.Which value is published under rated current Ie for catalog number 2744458?
For 2744458, rated current Ie is given as up to 41 A (IEC 60947-7-1). Compare it with the nameplate of the installed unit before ordering.
Q.Before ordering 2744458, which output current entry should be checked?
The output current entry quoted above is 2x 20 mA ±10 % (Loop current). Confirm this figure against the unit currently in the panel.
Q.Where can I find the terminal wire size data for 2744458?
It is listed in the specification table for Phoenix Contact 2744458 as 13. Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for 2744458?
Send the full catalog number 2744458, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 2744458.
Q.Can the 2744458 replace the unit currently installed in my panel?
Compare catalog number 2744458 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.