Phoenix Contact · Terminal Block
2700606 is a Phoenix Contact circuit breaker with Rated current Ie up to 41 A (IEC 60947-7-1); Rated operational voltage 800 V (IEC 60947-7-1); Breaking capacity Icu/Ics 500 V AC, 50 Hz, 1 min. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ieup to 41 A (IEC 60947-7-1)
-
Rated operational voltage800 V (IEC 60947-7-1)
-
Breaking capacity Icu/Ics500 V AC, 50 Hz, 1 min
-
Supply voltage7.5 V DC (see safety data)
Specifications
| Electrical |
| Rated current Ie |
up to 41 A (IEC 60947-7-1) |
| Rated operational voltage |
800 V (IEC 60947-7-1) |
| Breaking capacity Icu/Ics |
500 V AC, 50 Hz, 1 min |
| Supply voltage |
7.5 V DC (see safety data) |
| Output voltage |
24 V DC (U S - 1 V) |
| Output current |
max. 6 A (Total current of all outputs, -25 °C ... 50 °C) |
| Overload capacity |
Output can be destroyed |
| Rated speed |
500 kbps / 2 Mbps (can be switched) |
| I/O and communication |
| Bus interface |
48 Byte ((Operating mode: SafetyBridge 24 words)) |
| Mechanical |
| Dimensions (H x W x D) |
Housing dimensions |
| Weight |
341.1 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 1.5 mm² |
| Environment and compliance |
| Operating temperature |
-25 °C ... 55 °C |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact Terminal Block specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Terminal Block variants |
| Catalog number |
Rated operational voltage |
|
2700606 (this page) |
800 V (IEC 60947-7-1) |
| 2700270 |
800 V (IEC 60947-7-1) |
| 2700453 |
800 V (IEC 60947-7-1) |
| 2700464 |
800 V (IEC 60947-7-1) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 2700606 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 7.5 V DC (see safety data) — and switches or conditions the load within the up to 41 A (IEC 60947-7-1) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 2700606
Phoenix Contact 2700606 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 2700606; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Bus interface: 48 Byte ((Operating mode: SafetyBridge 24 words)) — Match it to the existing panel and upstream protection.
- Breaking capacity Icu/Ics: 500 V AC, 50 Hz, 1 min — Record it with the other nameplate data when sourcing a replacement.
- Weight: 341.1 g — Confirm the revision of the installed unit before a like-for-like replacement.
- Terminal wire size: 0.2 mm² ... 1.5 mm² — Use it as the reference when cross-checking a current-production equivalent.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about 2700606
Q.Before ordering 2700606, which operating temperature entry should be checked?
The operating temperature entry quoted above is -25 °C ... 55 °C. Use the value as the reference when sourcing a current-production equivalent.
Q.Where can I find the dimensions (H x W x D) data for 2700606?
It is listed in the specification table for Phoenix Contact 2700606 as Housing dimensions. Check the revision of the installed unit if the catalog number has been superseded.
Q.For 2700606, what does the specification table state about output current?
The specification table lists output current = max. 6 A (Total current of all outputs, -25 °C ... 50 °C) for Phoenix Contact 2700606. Compare it with the nameplate of the installed unit before ordering.
Q.What should I include in an enquiry for 2700606?
Send the full catalog number 2700606, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 2700606.
Q.Can the 2700606 replace the unit currently installed in my panel?
Compare catalog number 2700606 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.