Phoenix Contact · Terminal Block
2280310 is a Phoenix Contact terminal block with Rated current Ie up to 41 A (IEC 60947-7-1); Rated operational voltage 800 V (IEC 60947-7-1); Operating temperature -20 °C ... 50 °C. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ieup to 41 A (IEC 60947-7-1)
-
Rated operational voltage800 V (IEC 60947-7-1)
-
Operating temperature-20 °C ... 50 °C
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Rated current Ie |
up to 41 A (IEC 60947-7-1) |
| Rated operational voltage |
800 V (IEC 60947-7-1) |
| Rated insulation voltage Ui |
125 V |
| Tripping characteristic |
8 mm |
| Rated torque |
0.5 Nm ... 0.6 Nm |
| Mechanical |
| Weight |
84.27 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 4 mm² |
| Environment and compliance |
| Operating temperature |
-20 °C ... 50 °C |
| Certifications |
CE, UL, cULus |
Values follow the Phoenix Contact Terminal Block specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Terminal Block variants |
| Catalog number |
Rated current Ie |
Rated operational voltage |
Mounting |
|
2280310 (this page) |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
| 2280307 |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
| 2280336 |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
| 2280349 |
up to 41 A (IEC 60947-7-1) |
800 V (IEC 60947-7-1) |
35 mm DIN rail (IEC 60715) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 2280310 is the device-level element in a Phoenix Contact terminal block installation. It receives the field signals and control supply listed above — 800 V (IEC 60947-7-1) — and switches or conditions the load within the up to 41 A (IEC 60947-7-1) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 2280310
Phoenix Contact 2280310 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 2280310; verify the catalog number against your bill of materials before requesting a quotation.
- Certifications: CE, UL, cULus — Use it as the reference when cross-checking a current-production equivalent.
- Rated operational voltage: 800 V (IEC 60947-7-1) — Verify it in the project documentation before confirming the order.
- Rated insulation voltage Ui: 125 V — Check this value against the nameplate of the installed unit before ordering.
- Tripping characteristic: 8 mm — Match it to the existing panel and upstream protection.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about 2280310
Q.For 2280310, what does the specification table state about rated insulation voltage Ui?
The specification table lists rated insulation voltage Ui = 125 V for Phoenix Contact 2280310. Compare it with the nameplate of the installed unit before ordering.
Q.Which value is published under mounting for catalog number 2280310?
For 2280310, mounting is given as 35 mm DIN rail (IEC 60715). Confirm this figure against the unit currently in the panel.
Q.Before ordering 2280310, which rated operational voltage entry should be checked?
The rated operational voltage entry quoted above is 800 V (IEC 60947-7-1). Use the value as the reference when sourcing a current-production equivalent.
Q.Can the 2280310 replace the unit currently installed in my panel?
Compare catalog number 2280310 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for 2280310?
Send the full catalog number 2280310, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 2280310.