WAGO · Controller ETHERNET
750-880 is a WAGO Controller ETHERNET. Enclosure rating: IP20; Operating temperature: 0 … +55 °C; Mounting: DIN-35 rail; Conformity marking: CE. It is used in control panels, machine builds and spare-part replacements where the installed unit is matched to the original catalog number and a documented part is required.
-
Enclosure ratingIP20
-
Operating temperature0 … +55 °C
-
MountingDIN-35 rail
-
Conformity markingCE
-
Supply voltage (system)24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow
Specifications
| Technical data |
| Supply voltage (system) |
24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow |
| Supply voltage (field) |
24 VDC, SELV/PELV (-25 … +30 %); via power jumper contacts (supply via CAGE CLAMP ® connection; distribution via spring contact); External fuse required: 10 A slow-blow |
| Current consumption (system supply) |
450 mA |
| Total current (system supply) |
1,700 mA |
| Current carrying capacity (power jumper contacts) |
10 A |
| Isolation |
500 V system/field |
| Power supply efficiency (typ.) at nominal load (24 V) |
90 % |
| Number of outgoing power jumper contacts |
3 |
| Communications |
EtherNet/IP; Modbus (TCP, UDP); ETHERNET |
| ETHERNET protocols |
HTTP; BootP; DHCP; DNS; SNTP; FTP; SNMP |
| Transmission rate |
10/100 Mbit/s |
| Transmission medium (communication/fieldbus) |
Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length |
| Transmission performance |
Class D per EN 50173 |
| CPU |
32 bits |
| Environmental requirements |
| Pollution degree |
2 per IEC 61131-2 |
| Connection Data |
| Connection technology: system supply |
2 x CAGE CLAMP ® |
| Connection technology: field supply |
6 x CAGE CLAMP ® |
| Connection technology: communication/fieldbus |
EtherNet/IP TM : 2 x RJ-45; Modbus (TCP, UDP): 2 x RJ-45 |
| Connection technology: device configuration |
1 x Male connector; 4-pole |
| Connection type |
System/field supply |
Values follow the WAGO official technical data published for catalog number 750-880; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| WAGO Controller ETHERNET variants |
| Catalog number |
Enclosure rating |
Operating temperature |
Mounting |
| 750-842 |
IP20 |
0 … +55 °C |
DIN-35 rail |
|
750-880 (this page) |
IP20 |
0 … +55 °C |
DIN-35 rail |
| 750-881 |
IP20 |
0 … +55 °C |
DIN-35 rail |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 750-880 is the device-level element in a WAGO Controller ETHERNET installation. It receives the field signals and control supply listed above and switches or conditions the load within the ratings shown in the Specifications table. Wiring and protective devices are sized against enclosure rating IP20, operating temperature 0 … +55 °C, mounting DIN-35 rail — not against a generic assumption.
Typical installations place it in control panels, machine builds and spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides the mounting support listed above. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for WAGO 750-880
WAGO 750-880 — WAGO industrial component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the WAGO official specification for catalog number 750-880; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Enclosure rating: IP20 — Verify it in the project documentation before confirming the order.
- Operating temperature: 0 … +55 °C — Verify it in the project documentation before confirming the order.
- Mounting: DIN-35 rail — Verify it in the project documentation before confirming the order.
- Conformity marking: CE — Verify it in the project documentation before confirming the order.
- Supply voltage (system): 24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow — Verify it in the project documentation before confirming the order.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about 750-880
Q.Where can I find the supply voltage (system) data for 750-880?
It is listed in the specification table for WAGO 750-880 as 24 VDC, SELV/PELV (-25 … +30 %); via wiring interface (CAGE CLAMP ® connection); External fuse required: 2 A slow-blow. Use the value as the reference when sourcing a current-production equivalent.
Q.For 750-880, what does the specification table state about supply voltage (field)?
The specification table lists Supply voltage (field) = 24 VDC, SELV/PELV (-25 … +30 %); via power jumper contacts (supply via CAGE CLAMP ® connection; distribution via spring contact); External fuse required: 10 A slow-blow for WAGO 750-880. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under current consumption (system supply) for catalog number 750-880?
For 750-880, current consumption (system supply) is given as 450 mA. Compare it with the nameplate of the installed unit before ordering.
Q.What should I include in an enquiry for 750-880?
Send the full catalog number 750-880, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for WAGO 750-880.
Q.How do I confirm compatibility of 750-880 before ordering?
Match the catalog number 750-880 and the specification values listed above against the installed unit, then confirm the hardware revision where a revision-sensitive part is involved.