Phoenix Contact · Terminal Block
0270018 is a Phoenix Contact circuit breaker with Rated current Ie up to 41 A (IEC 60947-7-1); Tripping characteristic 9 mm; Rated operational voltage 800 V (IEC 60947-7-1). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ieup to 41 A (IEC 60947-7-1)
-
Tripping characteristic9 mm
-
Rated operational voltage800 V (IEC 60947-7-1)
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Rated current Ie |
up to 41 A (IEC 60947-7-1) |
| Rated operational voltage |
800 V (IEC 60947-7-1) |
| Tripping characteristic |
9 mm |
| Rated torque |
0.6 ... 0.8 Nm |
| Mechanical |
| Weight |
7.725 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal wire size |
0.2 mm² ... 4 mm² |
| Environment and compliance |
| Operating temperature |
-25 °C ... 55 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
| Certifications |
CE, UL, cULus |
| Humidity |
30 % ... 70 % |
Values follow the Phoenix Contact Terminal Block specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Terminal Block variants |
| Catalog number |
Tripping characteristic |
Rated operational voltage |
|
0270018 (this page) |
9 mm |
800 V (IEC 60947-7-1) |
| 0313085 |
11 mm |
800 V (IEC 60947-7-1) |
| 0404017 |
16 mm |
800 V (IEC 60947-7-1) |
| 0404046 |
16 mm |
800 V (IEC 60947-7-1) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 0270018 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 800 V (IEC 60947-7-1) — and switches or conditions the load within the up to 41 A (IEC 60947-7-1) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 0270018
Phoenix Contact 0270018 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 0270018; record the nameplate data of the unit being replaced before selecting an equivalent.
- Rated torque: 0.6 ... 0.8 Nm — Use it as the reference when cross-checking a current-production equivalent.
- Rated operational voltage: 800 V (IEC 60947-7-1) — Verify it in the project documentation before confirming the order.
- Certifications: CE, UL, cULus — Check this value against the nameplate of the installed unit before ordering.
- Terminal wire size: 0.2 mm² ... 4 mm² — Match it to the existing panel and upstream protection.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about 0270018
Q.Where can I find the tripping characteristic data for 0270018?
It is listed in the specification table for Phoenix Contact 0270018 as 9 mm. Use the value as the reference when sourcing a current-production equivalent.
Q.For 0270018, what does the specification table state about certifications?
The specification table lists certifications = CE, UL, cULus for Phoenix Contact 0270018. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under rated operational voltage for catalog number 0270018?
For 0270018, rated operational voltage is given as 800 V (IEC 60947-7-1). Compare it with the nameplate of the installed unit before ordering.
Q.Can the 0270018 replace the unit currently installed in my panel?
Compare catalog number 0270018 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for 0270018?
Send the full catalog number 0270018, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 0270018.