Keyence · circuit breaker
LK-H157 is a Keyence circuit breaker with Rated operational voltage <= 440 V AC; Breaking capacity Icu/Ics 0.01% of F.S. (F.S.= 80 mm 3.15" ); Supply voltage 10...30 V DC (IEC 60947-5-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated operational voltage<= 440 V AC
-
Breaking capacity Icu/Ics0.01% of F.S. (F.S.= 80 mm 3.15" )
-
Supply voltage10...30 V DC (IEC 60947-5-2)
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated operational voltage |
<= 440 V AC |
| Breaking capacity Icu/Ics |
0.01% of F.S. (F.S.= 80 mm 3.15" ) |
| Supply voltage |
10...30 V DC (IEC 60947-5-2) |
| Mechanical |
| Weight |
Approx. 300 g |
| Mounting |
Diffuse reflective / Specular reflective *1 |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C |
| Certifications |
CE, cULus |
| Humidity |
35 to 85 % RH (No condensation) |
Values follow the Keyence circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Keyence circuit breaker variants |
| Catalog number |
Breaking capacity Icu/Ics |
Rated operational voltage |
|
LK-H157 (this page) |
0.01% of F.S. (F.S.= 80 mm 3.15" ) |
<= 440 V AC |
| LK-H150 |
0.01% of F.S./°C (F.S.= 80 mm 3.15" ) |
<= 440 V AC |
| LK-H152 |
0.01% of F.S. (F.S.= 80 mm 3.15" ) |
<= 440 V AC |
| LK-H155 |
0.01% of F.S./°C (F.S.= 80 mm 3.15" ) |
<= 440 V AC |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Selection notes for Keyence LK-H157
Keyence LK-H157 — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number LK-H157; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.
- Operating temperature: -25...+60 °C — Use it as the reference when cross-checking a current-production equivalent.
- Rated operational voltage: <= 440 V AC — Verify it in the project documentation before confirming the order.
- Enclosure rating: IP20 (IEC 60529) — Check this value against the nameplate of the installed unit before ordering.
- Breaking capacity Icu/Ics: 0.01% of F.S. (F.S.= 80 mm 3.15" ) — Match it to the existing panel and upstream protection.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about LK-H157
Q.For LK-H157, what does the specification table state about supply voltage?
The specification table lists supply voltage = 10...30 V DC (IEC 60947-5-2) for Keyence LK-H157. Confirm this figure against the unit currently in the panel.
Q.Which value is published under humidity for catalog number LK-H157?
For LK-H157, humidity is given as 35 to 85 % RH (No condensation). Use the value as the reference when sourcing a current-production equivalent.
Q.Before ordering LK-H157, which weight entry should be checked?
The weight entry quoted above is Approx. 300 g. Check the revision of the installed unit if the catalog number has been superseded.
Q.How do I confirm compatibility of LK-H157 before ordering?
Match the catalog number LK-H157 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.What should I include in an enquiry for LK-H157?
Send the full catalog number LK-H157, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Keyence LK-H157.