Keyence · industrial component
FS-N10 is a Keyence industrial component with Supply voltage 10...30 V DC (IEC 60947-5-2); Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage10...30 V DC (IEC 60947-5-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
Specifications
| Electrical |
| Supply voltage |
10...30 V DC (IEC 60947-5-2) |
| I/O and communication |
| Response time |
< 1 ms |
| Mechanical |
| Weight |
Approx. 20 g |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
| Humidity |
35 to 85 % RH (No condensation) |
Values follow the Keyence industrial component specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Keyence industrial component variants |
| Catalog number |
Mounting |
|
FS-N10 (this page) |
DIN rail / panel |
| FS-N11CP |
DIN rail / panel |
| FS-N11MN |
DIN rail / panel |
| FS-N11N |
DIN rail / panel |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The FS-N10 is the device-level element in a Keyence industrial component installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Keyence FS-N10
Keyence FS-N10 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number FS-N10; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Response time: < 1 ms — Verify it in the project documentation before confirming the order.
- Operating temperature: 0...+55 °C (IEC 60068-2-1) — Check this value against the nameplate of the installed unit before ordering.
- Supply voltage: 10...30 V DC (IEC 60947-5-2) — Match it to the existing panel and upstream protection.
- Certifications: CE, cULus — Record it with the other nameplate data when sourcing a replacement.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about FS-N10
Q.Which value is published under operating temperature for catalog number FS-N10?
For FS-N10, operating temperature is given as 0...+55 °C (IEC 60068-2-1). Compare it with the nameplate of the installed unit before ordering.
Q.Before ordering FS-N10, which response time entry should be checked?
The response time entry quoted above is < 1 ms. Confirm this figure against the unit currently in the panel.
Q.Where can I find the enclosure rating data for FS-N10?
It is listed in the specification table for Keyence FS-N10 as IP20 (IEC 60529). Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for FS-N10?
Send the full catalog number FS-N10, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Keyence FS-N10.
Q.How do I confirm compatibility of FS-N10 before ordering?
Match the catalog number FS-N10 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.