Keyence · circuit breaker
LK-H057 is a Keyence circuit breaker with Rated operational voltage <= 440 V AC; Breaking capacity Icu/Ics 0.01% of F.S./°C (F.S.= 20 mm 0.79" ); Supply voltage 10...30 V DC (IEC 60947-5-2). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated operational voltage<= 440 V AC
-
Breaking capacity Icu/Ics0.01% of F.S./°C (F.S.= 20 mm 0.79" )
-
Supply voltage10...30 V DC (IEC 60947-5-2)
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated operational voltage |
<= 440 V AC |
| Breaking capacity Icu/Ics |
0.01% of F.S./°C (F.S.= 20 mm 0.79" ) |
| Supply voltage |
10...30 V DC (IEC 60947-5-2) |
| Mechanical |
| Weight |
Approx. 260 g |
| Mounting |
Diffuse reflective |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+60 °C |
| Certifications |
CE, cULus |
| Humidity |
35 to 85 % RH (No condensation) |
Values follow the Keyence circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Keyence circuit breaker variants |
| Catalog number |
Breaking capacity Icu/Ics |
Rated operational voltage |
|
LK-H057 (this page) |
0.01% of F.S./°C (F.S.= 20 mm 0.79" ) |
<= 440 V AC |
| LK-H057K |
0.01% of F.S. (F.S.= 20 mm 0.79" ) |
<= 440 V AC |
| LK-H050 |
0.01% of F.S./°C (F.S.= 20 mm 0.79" ) |
<= 440 V AC |
| LK-H052 |
0.01% of F.S./°C (F.S.= 20 mm 0.79" ) |
<= 440 V AC |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Selection notes for Keyence LK-H057
Keyence LK-H057 — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number LK-H057; verify the catalog number against your bill of materials before requesting a quotation.
- Rated operational voltage: <= 440 V AC — Match it to the existing panel and upstream protection.
- Supply voltage: 10...30 V DC (IEC 60947-5-2) — Record it with the other nameplate data when sourcing a replacement.
- Weight: Approx. 260 g — Confirm the revision of the installed unit before a like-for-like replacement.
- Humidity: 35 to 85 % RH (No condensation) — Use it as the reference when cross-checking a current-production equivalent.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about LK-H057
Q.Where can I find the certifications data for LK-H057?
It is listed in the specification table for Keyence LK-H057 as CE, cULus. Compare it with the nameplate of the installed unit before ordering.
Q.For LK-H057, what does the specification table state about humidity?
The specification table lists humidity = 35 to 85 % RH (No condensation) for Keyence LK-H057. Confirm this figure against the unit currently in the panel.
Q.Which value is published under operating temperature for catalog number LK-H057?
For LK-H057, operating temperature is given as -25...+60 °C. Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for LK-H057?
Send the full catalog number LK-H057, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Keyence LK-H057.
Q.How do I confirm compatibility of LK-H057 before ordering?
Match the catalog number LK-H057 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.