IFM · Inductive proximity sensor
IG0092 is an IFM circuit breaker with Breaking capacity Icu/Ics no; Supply voltage 10...30 V DC (IEC 60947-5-2); Enclosure rating IP67 (IEC 60529). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Breaking capacity Icu/Icsno
-
Supply voltage10...30 V DC (IEC 60947-5-2)
-
Enclosure ratingIP67 (IEC 60529)
-
Mountingnon-flush mountable
Specifications
| Electrical |
| Breaking capacity Icu/Ics |
no |
| Supply voltage |
10...30 V DC (IEC 60947-5-2) |
| Frequency |
25 Hz |
| Overload capacity |
no |
| Mechanical |
| Dimensions (H x W x D) |
M18 x 1 / L = 80 mm |
| Weight |
118.2 g |
| Mounting |
non-flush mountable |
| Enclosure rating |
IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the IFM Inductive proximity sensor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| IFM Inductive proximity sensor variants |
| Catalog number |
Breaking capacity Icu/Ics |
|
IG0092 (this page) |
no |
| IG0093 |
no |
| IG0006 |
no |
| IG0011 |
no |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The IG0092 is the device-level element in an IFM circuit breaker installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides non-flush mountable support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for IFM IG0092
IFM IG0092 — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number IG0092; verify the catalog number against your bill of materials before requesting a quotation.
- Mounting: non-flush mountable — Check this value against the nameplate of the installed unit before ordering.
- Frequency: 25 Hz — Match it to the existing panel and upstream protection.
- Certifications: CE, cULus — Record it with the other nameplate data when sourcing a replacement.
- Supply voltage: 10...30 V DC (IEC 60947-5-2) — Confirm the revision of the installed unit before a like-for-like replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about IG0092
Q.For IG0092, what does the specification table state about supply voltage?
The specification table lists supply voltage = 10...30 V DC (IEC 60947-5-2) for IFM IG0092. Check the revision of the installed unit if the catalog number has been superseded.
Q.Which value is published under certifications for catalog number IG0092?
For IG0092, certifications is given as CE, cULus. Compare it with the nameplate of the installed unit before ordering.
Q.Before ordering IG0092, which mounting entry should be checked?
The mounting entry quoted above is non-flush mountable. Confirm this figure against the unit currently in the panel.
Q.How do I confirm compatibility of IG0092 before ordering?
Match the catalog number IG0092 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the IG0092 replace the unit currently installed in my panel?
Compare catalog number IG0092 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.