Delta DVP14SS211R2 PLC Controller

SKU: DVP14SS211R2
Regular price $228.66
In stock (90 units)
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

Delta · DVP-SS2

DVP14SS211R2 is a Delta PLC Controller. It is used in packaging machines, conveyor transfer cells, small process skids where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Total I/O494 (14 + 480)
  • Supply voltage24 V DC (IEC 61131-2)
  • Enclosure ratingIP20 (IEC 60529)

Specifications

Electrical
Supply voltage 24 V DC (IEC 61131-2)
Rated speed Supports 4 points (Y0 ~ Y3) of independent high-speed (max. 10kHz) pulse output
I/O and communication
Total I/O 494 (14 + 480)
Mechanical
Mounting 35 mm DIN rail (IEC 60715)
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature 0...+55 °C (IEC 60068-2-1)
Certifications CE, UL, cULus

Product type and series follow the official Delta download-centre catalogue search for this model which lists DVP14SS211R2 under the Delta product line; the product type published for this catalog number is "PLC Controller". Source: https://downloadcenter.deltaww.com/en-US/DownloadCenter?q=DVP14SS211R2. Numeric ratings in the table above are the values carried on this page and must be confirmed against the original Delta manufacturer datasheet before they are treated as this catalog number's ratings; they are not estimated here.

Model comparison in the same family

DVP12SS211SDVP-SS2-DVP14SS211TDVP28SS211R
Delta DVP-SS2 variants
Catalog number Total I/O Supply voltage
DVP14SS211R2 (this page) 494 (14 + 480) 24 V DC (IEC 61131-2)
24 V DC (IEC 61131-2)
24 V DC (IEC 61131-2)
24 V DC (IEC 61131-2)

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The DVP14SS211R2 is the controller element in a Delta control installation. It receives the field signals and control supply listed above and switches or conditions the load within the rated values shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in packaging machines, conveyor transfer cells, small process skids, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for Delta DVP14SS211R2

Delta DVP14SS211R2 — PLC / CPU module used as the device-level control core in an automation panel, handling logic, timing and communication tasks. The figures below are taken from the specification table on this page for catalog number DVP14SS211R2; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.

  • Supply voltage: 24 V DC (IEC 61131-2) — Check this value against the nameplate of the installed unit before ordering.
  • Enclosure rating: IP20 (IEC 60529) — Match it to the existing panel and upstream protection.
  • Operating temperature: 0...+55 °C (IEC 60068-2-1) — Record it with the other nameplate data when sourcing a replacement.
  • Certifications: CE, UL, cULus — Confirm the revision of the installed unit before a like-for-like replacement.

Cross-check the ratings above with the installed device before confirming the order.

Common questions about DVP14SS211R2

Q.Which official Delta document defines DVP14SS211R2?

The official Delta download-centre catalogue search for this model lists DVP14SS211R2 under the Delta product line, and the product type published for this catalog number is "PLC Controller". The document and its official catalogue record are publicly retrievable at https://downloadcenter.deltaww.com/en-US/DownloadCenter?q=DVP14SS211R2. Use that document as the authority for ratings and installation conditions before ordering.

Q.For DVP14SS211R2, what does the specification table state about operating temperature?

The specification table lists operating temperature = 0...+55 °C (IEC 60068-2-1) for Delta DVP14SS211R2. Use the value as the reference when sourcing a current-production equivalent.

Q.Which value is published under enclosure rating for catalog number DVP14SS211R2?

For DVP14SS211R2, enclosure rating is given as IP20 (IEC 60529). Check the revision of the installed unit if the catalog number has been superseded.

Q.Before ordering DVP14SS211R2, which supply voltage entry should be checked?

The supply voltage entry quoted above is 24 V DC (IEC 61131-2). Compare it with the nameplate of the installed unit before ordering.

Q.What should I include in an enquiry for DVP14SS211R2?

Send the full catalog number DVP14SS211R2, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Delta DVP14SS211R2.

Q.How do I confirm compatibility of DVP14SS211R2 before ordering?

Match the catalog number DVP14SS211R2 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!