Delta · Delta switching power supply
DRP024V480W3BN is a Delta variable-frequency drive with Overload capacity > 200% of rated load current, Hiccup Mode,; Enclosure rating IP20 (IEC 60529); Frequency 47-63 Hz. It is used in pump sets, conveyor belts, fan and compressor drives where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Overload capacity> 200% of rated load current, Hiccup Mode,
-
Enclosure ratingIP20 (IEC 60529)
-
Frequency47-63 Hz
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Input voltage range |
85...264 V AC / 110...300 V DC (IEC 61010) |
| Output current |
20.0 A (continuously operating at 24 V) |
| Efficiency |
up to 94 % |
| Frequency |
47-63 Hz |
| Overload capacity |
> 200% of rated load current, Hiccup Mode, |
| Mechanical |
| Dimensions (H x W x D) |
121 x 140 x 117.3 mm (4.76 x 5.51 x 4.62 inch) |
| Weight |
1.35 kg (2.98 lb) |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Delta Delta switching power supply specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Delta Delta switching power supply variants |
| Catalog number |
Overload capacity |
Frequency |
Rated operational voltage |
|
DRP024V480W3BN (this page) |
> 200% of rated load current, Hiccup Mode, |
47-63 Hz |
— |
| DRP024V060W1AA |
150% for 60 s |
50/60 Hz |
1-phase 200-240 V / 3-phase 380-480 V |
| DRP024V060W1AZ |
150% for 60 s |
50/60 Hz |
1-phase 200-240 V / 3-phase 380-480 V |
| DRP024V120W3BN |
> 150% of rated load current, Hiccup Mode, |
47-63 Hz |
— |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The DRP024V480W3BN is the device-level element in a Delta variable-frequency drive installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in pump sets, conveyor belts, fan and compressor drives, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Delta DRP024V480W3BN
Delta DRP024V480W3BN — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number DRP024V480W3BN; verify the catalog number against your bill of materials before requesting a quotation.
- Overload capacity: > 200% of rated load current, Hiccup Mode, — Record it with the other nameplate data when sourcing a replacement.
- Input voltage range: 85...264 V AC / 110...300 V DC (IEC 61010) — Confirm the revision of the installed unit before a like-for-like replacement.
- Dimensions (H x W x D): 121 x 140 x 117.3 mm (4.76 x 5.51 x 4.62 inch) — Use it as the reference when cross-checking a current-production equivalent.
- Output current: 20.0 A (continuously operating at 24 V) — Verify it in the project documentation before confirming the order.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about DRP024V480W3BN
Q.Before ordering DRP024V480W3BN, which dimensions (H x W x D) entry should be checked?
The dimensions (H x W x D) entry quoted above is 121 x 140 x 117.3 mm (4.76 x 5.51 x 4.62 inch). Confirm this figure against the unit currently in the panel.
Q.Where can I find the frequency data for DRP024V480W3BN?
It is listed in the specification table for Delta DRP024V480W3BN as 47-63 Hz. Use the value as the reference when sourcing a current-production equivalent.
Q.For DRP024V480W3BN, what does the specification table state about input voltage range?
The specification table lists input voltage range = 85...264 V AC / 110...300 V DC (IEC 61010) for Delta DRP024V480W3BN. Check the revision of the installed unit if the catalog number has been superseded.
Q.How do I confirm compatibility of DRP024V480W3BN before ordering?
Match the catalog number DRP024V480W3BN and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the DRP024V480W3BN replace the unit currently installed in my panel?
Compare catalog number DRP024V480W3BN and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.