Delta · Delta switching power supply
DRP024V060W1AA is a Delta variable-frequency drive with Rated operational voltage 1-phase 200-240 V / 3-phase 380-480 V; Overload capacity 150% for 60 s; Enclosure rating IP20 (IEC 60529). It is used in pump sets, conveyor belts, fan and compressor drives where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated operational voltage1-phase 200-240 V / 3-phase 380-480 V
-
Overload capacity150% for 60 s
-
Enclosure ratingIP20 (IEC 60529)
-
Frequency50/60 Hz
Specifications
| Electrical |
| Rated operational voltage |
1-phase 200-240 V / 3-phase 380-480 V |
| Input voltage range |
85...264 V AC / 110...300 V DC (IEC 61010) |
| Output current |
2.50 A (continuously operating at 24V) |
| Efficiency |
up to 94 % |
| Frequency |
50/60 Hz |
| Overload capacity |
150% for 60 s |
| Mechanical |
| Dimensions (H x W x D) |
121 x 32 x 120 mm (4.76 x 1.26 x 4.72 inch) |
| Weight |
0.37 kg (0.82 lb) |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+40 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Delta Delta switching power supply specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Delta Delta switching power supply variants |
| Catalog number |
Overload capacity |
Frequency |
Rated operational voltage |
|
DRP024V060W1AA (this page) |
150% for 60 s |
50/60 Hz |
1-phase 200-240 V / 3-phase 380-480 V |
| DRP024V060W1AZ |
150% for 60 s |
50/60 Hz |
1-phase 200-240 V / 3-phase 380-480 V |
| DRP024V120W3BN |
> 150% of rated load current, Hiccup Mode, |
47-63 Hz |
— |
| DRP024V480W3BN |
> 200% of rated load current, Hiccup Mode, |
47-63 Hz |
— |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The DRP024V060W1AA is the device-level element in a Delta variable-frequency drive installation. It receives the field signals and control supply listed above — 1-phase 200-240 V / 3-phase 380-480 V — and switches or conditions the load within the 1-phase 200-240 V / 3-phase 380-480 V ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in pump sets, conveyor belts, fan and compressor drives, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Delta DRP024V060W1AA
Delta DRP024V060W1AA — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number DRP024V060W1AA; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Overload capacity: 150% for 60 s — Match it to the existing panel and upstream protection.
- Enclosure rating: IP20 (IEC 60529) — Record it with the other nameplate data when sourcing a replacement.
- Rated operational voltage: 1-phase 200-240 V / 3-phase 380-480 V — Confirm the revision of the installed unit before a like-for-like replacement.
- Output current: 2.50 A (continuously operating at 24V) — Use it as the reference when cross-checking a current-production equivalent.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about DRP024V060W1AA
Q.Before ordering DRP024V060W1AA, which dimensions (H x W x D) entry should be checked?
The dimensions (H x W x D) entry quoted above is 121 x 32 x 120 mm (4.76 x 1.26 x 4.72 inch). Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the weight data for DRP024V060W1AA?
It is listed in the specification table for Delta DRP024V060W1AA as 0.37 kg (0.82 lb). Compare it with the nameplate of the installed unit before ordering.
Q.For DRP024V060W1AA, what does the specification table state about enclosure rating?
The specification table lists enclosure rating = IP20 (IEC 60529) for Delta DRP024V060W1AA. Confirm this figure against the unit currently in the panel.
Q.How do I confirm compatibility of DRP024V060W1AA before ordering?
Match the catalog number DRP024V060W1AA and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.What should I include in an enquiry for DRP024V060W1AA?
Send the full catalog number DRP024V060W1AA, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Delta DRP024V060W1AA.