Delta · variable-frequency drive
DRL-24V120W1EN is a Delta variable-frequency drive with Rated operational voltage 1-phase 200-240 V / 3-phase 380-480 V; Overload capacity 150% for 60 s; Enclosure rating IP20 (IEC 60529). It is used in pump sets, conveyor belts, fan and compressor drives where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated operational voltage1-phase 200-240 V / 3-phase 380-480 V
-
Overload capacity150% for 60 s
-
Enclosure ratingIP20 (IEC 60529)
-
Frequency50/60 Hz
Specifications
| Electrical |
| Rated operational voltage |
1-phase 200-240 V / 3-phase 380-480 V |
| Input voltage range |
85...264 V AC / 110...300 V DC (IEC 61010) |
| Efficiency |
up to 94 % |
| Frequency |
50/60 Hz |
| Overload capacity |
150% for 60 s |
| Mechanical |
| Dimensions (H x W x D) |
123.6 x 30 x 116.8 mm (4.87 x 1.18 x 4.60 inch) |
| Weight |
0.45 kg (0.99 lb) |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+40 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the Delta variable-frequency drive specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Delta variable-frequency drive variants |
| Catalog number |
Overload capacity |
Frequency |
|
DRL-24V120W1EN (this page) |
150% for 60 s |
50/60 Hz |
| DRL-24V120W1AA |
105-150% of rated load current, Continuous current |
47-63 Hz |
| DRL-24V120W1AS |
105-150% of rated load current, Continuous current |
47-63 Hz |
| DRL-24V240W1AA |
105-150% of rated load current, Continuous current |
47-63 Hz |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The DRL-24V120W1EN is the device-level element in a Delta variable-frequency drive installation. It receives the field signals and control supply listed above — 1-phase 200-240 V / 3-phase 380-480 V — and switches or conditions the load within the 1-phase 200-240 V / 3-phase 380-480 V ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in pump sets, conveyor belts, fan and compressor drives, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Delta DRL-24V120W1EN
Delta DRL-24V120W1EN — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number DRL-24V120W1EN; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Efficiency: up to 94 % — Verify it in the project documentation before confirming the order.
- Enclosure rating: IP20 (IEC 60529) — Check this value against the nameplate of the installed unit before ordering.
- Input voltage range: 85...264 V AC / 110...300 V DC (IEC 61010) — Match it to the existing panel and upstream protection.
- Frequency: 50/60 Hz — Record it with the other nameplate data when sourcing a replacement.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about DRL-24V120W1EN
Q.For DRL-24V120W1EN, what does the specification table state about weight?
The specification table lists weight = 0.45 kg (0.99 lb) for Delta DRL-24V120W1EN. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under efficiency for catalog number DRL-24V120W1EN?
For DRL-24V120W1EN, efficiency is given as up to 94 %. Check the revision of the installed unit if the catalog number has been superseded.
Q.Before ordering DRL-24V120W1EN, which rated operational voltage entry should be checked?
The rated operational voltage entry quoted above is 1-phase 200-240 V / 3-phase 380-480 V. Compare it with the nameplate of the installed unit before ordering.
Q.How do I confirm compatibility of DRL-24V120W1EN before ordering?
Match the catalog number DRL-24V120W1EN and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the DRL-24V120W1EN replace the unit currently installed in my panel?
Compare catalog number DRL-24V120W1EN and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.