Beckhoff · Inductive Sensor
IE2403-0000 is a Beckhoff inductive sensor with Supply voltage 10...30 V DC; Enclosure rating IP67 (IEC 60529); Response time <= 1500 Hz switching frequency. It is used in conveyor object detection, machine guarding, position feedback where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage10...30 V DC
-
Enclosure ratingIP67 (IEC 60529)
-
Response time<= 1500 Hz switching frequency
-
Operating temperature-25...+70 °C
Specifications
| Electrical |
| Supply voltage |
10...30 V DC |
| I/O and communication |
| Communication ports |
EtherCAT, Ethernet |
| Response time |
<= 1500 Hz switching frequency |
| Mechanical |
| Enclosure rating |
IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C |
| Certifications |
CE, UL, cULus |
Values follow the Beckhoff Inductive Sensor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Beckhoff Inductive Sensor variants |
| Catalog number |
Supply voltage |
|
IE2403-0000 (this page) |
10...30 V DC |
| IE1001 |
10...30 V DC |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The IE2403-0000 is the device-level element in a Beckhoff inductive sensor installation. It receives the field signals and control supply listed above — 10...30 V DC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in conveyor object detection, machine guarding, position feedback, where the unit is matched to the original catalog number and the enclosure provides standard panel or DIN-rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Beckhoff IE2403-0000
Beckhoff IE2403-0000 — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number IE2403-0000; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Communication ports: EtherCAT, Ethernet — Record it with the other nameplate data when sourcing a replacement.
- Enclosure rating: IP67 (IEC 60529) — Confirm the revision of the installed unit before a like-for-like replacement.
- Supply voltage: 10...30 V DC — Use it as the reference when cross-checking a current-production equivalent.
- Response time: <= 1500 Hz switching frequency — Verify it in the project documentation before confirming the order.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about IE2403-0000
Q.For IE2403-0000, what does the specification table state about certifications?
The specification table lists certifications = CE, UL, cULus for Beckhoff IE2403-0000. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under supply voltage for catalog number IE2403-0000?
For IE2403-0000, supply voltage is given as 10...30 V DC. Check the revision of the installed unit if the catalog number has been superseded.
Q.Before ordering IE2403-0000, which response time entry should be checked?
The response time entry quoted above is <= 1500 Hz switching frequency. Compare it with the nameplate of the installed unit before ordering.
Q.Can the IE2403-0000 replace the unit currently installed in my panel?
Compare catalog number IE2403-0000 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.How do I confirm compatibility of IE2403-0000 before ordering?
Match the catalog number IE2403-0000 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.