B&R · B&R X20 I/O module
X20SO4120 is a B&R circuit breaker with Breaking capacity Icu/Ics See section "Inrush current behavior for output channels".; Supply voltage 24 V DC (IEC 61131-2); Enclosure rating IP20 (IEC 60529). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Breaking capacity Icu/IcsSee section "Inrush current behavior for output channels".
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
-
Mounting35 mm DIN rail (IEC 60715)
Specifications
| Electrical |
| Rated insulation voltage Ui |
500 V eff |
| Breaking capacity Icu/Ics |
See section "Inrush current behavior for output channels". |
| Supply voltage |
24 V DC (IEC 61131-2) |
| Output current |
2 A |
| Frequency |
See section "Inrush current behavior for output channels". |
| I/O and communication |
| Bus interface |
0.25 W |
| Communication ports |
POWERLINK, Ethernet |
| Mechanical |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the B&R B&R X20 I/O module specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| B&R B&R X20 I/O module variants |
| Catalog number |
Breaking capacity Icu/Ics |
|
X20SO4120 (this page) |
See section "Inrush current behavior for output channels". |
| X20SO4110 |
See section "Inrush current behavior for output channels". |
| X20SO6300 |
See section "Inrush current behavior for output channels". |
| X20SC2212 |
Type 1 |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The X20SO4120 is the device-level element in a B&R circuit breaker installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial X20SO4120
Industrial X20SO4120 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number X20SO4120; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Certifications: CE, UL, cULus — Confirm the revision of the installed unit before a like-for-like replacement.
- Breaking capacity Icu/Ics: See section "Inrush current behavior for output channels". — Use it as the reference when cross-checking a current-production equivalent.
- Bus interface: 0.25 W — Verify it in the project documentation before confirming the order.
- Communication ports: POWERLINK, Ethernet — Check this value against the nameplate of the installed unit before ordering.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about X20SO4120
Q.Before ordering X20SO4120, which operating temperature entry should be checked?
The operating temperature entry quoted above is 0...+55 °C (IEC 60068-2-1). Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the frequency data for X20SO4120?
It is listed in the specification table for Industrial X20SO4120 as See section "Inrush current behavior for output channels".. Compare it with the nameplate of the installed unit before ordering.
Q.For X20SO4120, what does the specification table state about supply voltage?
The specification table lists supply voltage = 24 V DC (IEC 61131-2) for Industrial X20SO4120. Confirm this figure against the unit currently in the panel.
Q.Can the X20SO4120 replace the unit currently installed in my panel?
Compare catalog number X20SO4120 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.
Q.What should I include in an enquiry for X20SO4120?
Send the full catalog number X20SO4120, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Industrial X20SO4120.