X20SC2212 X20 System Module | B&R
The B&R X20SC2212 is a x20 system module. The listed technical data shows rated IP20, based on the manufacturer's datasheet. It is supplied by SHLY-PLC, an independent industrial-automation distributor: every unit is visually inspected and functionally checked before dispatch, held in ready stock and shipped worldwide for maintenance, spares and retrofit use. Share your application or existing part number and our team will confirm fitment and comparable in-stock alternatives.
Features
-
Safe digital outputs: 0.075.
-
Nominal output current: 0.5 A.
-
Output protection: See section "Inrush current behavior for output channels".
-
Test pulse length: Max. 500 µs.
Specifications
Technical parameters compiled from the manufacturer data sheet and reference documentation.
| Technical Specifications |
| Inputs & Outputs |
| I/O module |
6 safe type A digital inputs, 6 pulse outputs, 24 VDC, 2 safe type B1 digital outputs, 24 VDC, 0.5 A, OSSD <500 µs |
| Other |
| Module run/error |
Yes, using LED status indicator and software |
| Scope |
Module |
| Function |
Module functionality |
| Standalone mode |
No |
| Bus |
0.25 W |
| Internal I/O |
1.4 W |
| Safe digital outputs |
0.075 |
| Pulse outputs |
0.264 |
| Channel - Channel |
No |
| CE |
Yes |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user's manual) FTZÚ 09 ATEX 0083X |
| HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV |
Temperature: A (0 to 45°C) Humidity: B (up to 100%) Vibration: A (0.7 g) EMC: B (bridge and open deck) |
| LR |
ENV1 |
| BV |
EC21B Temperature: 5 - 45°C Vibration: 0.7 g EMC: Bridge and open deck |
| B&R ID code |
0xBDA5 |
| Status indicators |
I/O function per channel, operating state, module status |
| Note |
See section "Safety characteristics". |
| Nominal voltage |
24 VDC |
| Voltage range |
24 VDC -15% / +20% |
| Hardware |
≤150 μs |
| Software |
Configurable between 0 and 500 ms |
| Low |
<5 VDC |
| High |
>15 VDC |
| Quantity |
6 |
| Variant |
Type A |
| Input characteristics per EN 61131-2 |
Type 1 |
| Input circuit |
Sink |
| Input voltage |
24 VDC -15% / +20% |
| Input current at 24 VDC |
Min. 2 mA to max. 3.28 mA |
| Error detection time |
100 ms |
| Quantity |
2 |
| Variant |
FET, 2x positive switching, type B1, output level readable |
| Nominal output current |
0.5 A |
| Total nominal current |
1 A |
| Output protection |
See section "Inrush current behavior for output channels". |
| Braking voltage when switching off inductive loads |
Max. 45 VDC |
| Error detection time |
1 s |
| Leakage current when the output is switched off |
<500 µA |
| R DS(on) |
150 mΩ |
| Switching voltage |
I/O power supply minus voltage drop due to R DS(on) |
| Test pulse length |
Max. 500 µs |
| Max. capacitive load |
100 nF |
| I OUT |
<1 mA |
| I GND |
<180 mA |
| Variant |
Push-Pull |
| Nominal output current |
20 mA |
| Output protection |
Shutdown of individual channels in the event of overload or short circuit |
| Peak short-circuit current |
25 A for 15 µs |
| Leakage current when the output is switched off |
0.1 mA |
| R DS(on) |
110 Ω |
| Total nominal current |
120 mA |
| Horizontal |
Yes |
| Installation elevation above sea level |
0 to 2000 m, no limitation |
| Degree of protection per EN 60529 |
IP20 |
| Vertical mounting orientation |
0 to 50°C |
| Derating |
See section "Derating". |
| Storage |
-40 to 85°C |
| Operation |
5 to 95%, non-condensing |
| Note |
Order 1x safety-keyed terminal block separately. Order 1x safety-keyed bus module separately. |
| Pitch |
25 +0.2 mm |
Compatibility & Cross-References
Model variants, options and firmware revisions can affect fitment. Before ordering the B&R X20SC2212 x20 system module, share your existing part number or project requirements and our team will cross-reference comparable in-stock B&R units and verify compatibility. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for identification only.
Applications
- Distributed digital and analog signal connection between field devices and the controller.
- Cabinet and machine I/O expansion for sensors, switches and actuators.
- Retrofit and spare module replacement in installed I/O systems.
- Flexible I/O configuration for modular machine builds.
Warranty
-
Availability: X20SC2212 is stocked for prompt shipment; contact us for current quantity and lead time.
-
Inspection & testing: each unit is visually inspected and functionally checked before packing.
-
Delivery: in-stock orders placed before 14:00 ship the same business day; standard worldwide delivery is about 5-8 business days, express shipping is available, and orders over $500 ship free.
-
Warranty & returns: covered by our supplier warranty and standard returns policy; contact our team for full terms.
Independent supplier: B&R part X20SC2212 is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.
Frequently Asked Questions
Q: What condition is the X20SC2212 supplied in?
A: Each X20SC2212 is inspected and functionally checked before sale. Contact us for the current stock condition and quantity.
Q: How quickly can the X20SC2212 ship?
A: In-stock orders placed before 14:00 ship the same business day. Standard worldwide delivery is about 5-8 business days, express shipping is available and orders over $500 ship free.
Q: Can you confirm compatibility or a replacement for the X20SC2212?
A: Yes. Share your existing part number or application and our technical team will verify compatibility and provide cross-references to comparable in-stock models.
X20SC2212 · Technical reference data · Independently supplied by SHLY-PLC