B&R · B&R X20 I/O module
X20PS2100 is a B&R power supply with Efficiency >=90%; Input voltage range 85...264 V AC; Supply voltage 100...240 V AC. It is used in DIN-rail control cabinets, sensor and relay supplies, backplane bus power where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Efficiency>=90%
-
Input voltage range85...264 V AC
-
Supply voltage100...240 V AC
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Supply voltage |
100...240 V AC |
| Input voltage range |
85...264 V AC |
| Efficiency |
>=90% |
| I/O and communication |
| Bus interface |
0.2 W |
| Communication ports |
POWERLINK, Ethernet |
| Mechanical |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the B&R B&R X20 I/O module specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| B&R B&R X20 I/O module variants |
| Catalog number |
Efficiency |
|
X20PS2100 (this page) |
>=90% |
| X20PS2110 |
>=90% |
| X20PS3300 |
up to 94 % |
| X20PS3310 |
up to 94 % |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The X20PS2100 is the device-level element in a B&R power supply installation. It receives the field signals and control supply listed above — 100...240 V AC — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in DIN-rail control cabinets, sensor and relay supplies, backplane bus power, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial X20PS2100
Industrial X20PS2100 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number X20PS2100; record the nameplate data of the unit being replaced before selecting an equivalent.
- Efficiency: >=90% — Match it to the existing panel and upstream protection.
- Bus interface: 0.2 W — Record it with the other nameplate data when sourcing a replacement.
- Enclosure rating: IP20 (IEC 60529) — Confirm the revision of the installed unit before a like-for-like replacement.
- Mounting: 35 mm DIN rail (IEC 60715) — Use it as the reference when cross-checking a current-production equivalent.
For a discontinued unit, match function and electrical ratings rather than the label alone.
Common questions about X20PS2100
Q.Which value is published under communication ports for catalog number X20PS2100?
For X20PS2100, communication ports is given as POWERLINK, Ethernet. Use the value as the reference when sourcing a current-production equivalent.
Q.Before ordering X20PS2100, which operating temperature entry should be checked?
The operating temperature entry quoted above is 0...+55 °C (IEC 60068-2-1). Check the revision of the installed unit if the catalog number has been superseded.
Q.Where can I find the efficiency data for X20PS2100?
It is listed in the specification table for Industrial X20PS2100 as >=90%. Compare it with the nameplate of the installed unit before ordering.
Q.How do I confirm compatibility of X20PS2100 before ordering?
Match the catalog number X20PS2100 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the X20PS2100 replace the unit currently installed in my panel?
Compare catalog number X20PS2100 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.