Allen-Bradley · 2080-OF2
2080-OF2 is an Allen-Bradley 2080-OF2 — Micro800 2 Point Analog Output Plug-In. Official specification values published for this catalog number: Operating temperature -20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock);Mounting torque 0.2 nm;Shock IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating.
-
Operating temperature-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock)
-
Mounting torque0.2 nm
-
ShockIEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating
-
Terminal screw torque0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver)
Specifications
| Electrical |
| Load range on voltage output |
> 1k Ω @ 10V DC |
| Resistive load on current output |
0...500 Ω (includes wire resistance) |
| Analogue inputs configurable |
False |
| Analogue outputs configurable |
True |
| Channel to channel isolation |
Non-isolation |
| Current load on voltage output, max |
10 mA |
| Current range |
0 mA |
| D/A Conversion rate (all channels), max |
2.5 ms |
| Input group to bus isolation |
Non-isolation |
| Input signal, configurable |
False |
| Input, current |
False |
| Input, resistance thermometer |
False |
| Input, resistor |
False |
| Input, thermocouple |
False |
| Input, voltage |
False |
| Number of analogue outputs |
2 |
| Output count range |
0 to 65535 |
| Output error |
Voltage: ±1.5% @ over full temperature range, -20...65°C (-4...149°F), Current: ±2.0% @ over full temperature range, -20...65°C (-4...149°F) |
| Output overvoltage protection |
True |
| Output signal configurable |
True |
| Output, current |
True |
| Output, voltage |
True |
| Overall accuracy |
Voltage terminal: ±1% full scale @ 25°C, Current terminal: ±1% full scale @ 25°C |
| Resolution of the analogue outputs |
12 bit |
| Type of electric connection |
Screw connection |
| Voltage ranges |
0 |
| Wire size |
Solid: 0.14 mm2 AWG)...1.5 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum, Stranded: 0.14 mm2 AWG)...1.0 mm2 AWG) @ Rated @ 90 °C (194 °F) insulation maximum |
| I/O Isolation |
None |
| Power consumption |
<60mA @ 24V |
| Mechanical |
| Mounting torque |
0.2 nm |
| Terminal screw torque |
0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) |
| Environment and compliance |
| Shock |
IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating |
| Vibration |
IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz |
| SIL according to IEC 61508 |
None |
| Temperature Rating |
-20…65 °C (-4…149 °F) |
| Conducted RF immunity |
IEC 61000-4-6, 10V rms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz |
| EFT/B immunity |
IEC 61000-4-4: ±2kV @ 5kHz on shielded ports |
| ESD immunity |
IEC 61000-4-2: 6 kV contact discharges, 8 kV air discharges |
| Emissions |
CISPR 11 (IEC 61000-6-4): Class A |
| Nonoperating temperature |
-40...85 °C (-40...185 °F), IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold), IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat), IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock) |
| North American temperature code |
T4 |
| Operating altitude |
2000 m |
| Operating temperature |
-20...65 °C (-4...149 °F): IEC 60068-2-1 (Test Ad, Operating Cold), IEC 60068-2-2 (Test Bd, operating dry heat), IEC 60068-2-14 (Test Nb, operating thermal shock) |
| Radiated RF immunity |
IEC 61000-4-3: 10V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 900 MHz, 10V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz, 10V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz, |
| Relative humidity |
IEC 60068-2-30 (Test Db, unpackaged dA heat), 5...95% noncondensing |
| Surge transient immunity |
IEC 61000-4-5: ±2 kV line-earth(CM) on shielded ports |
| Surrounding air temperature, max |
65 °C |
| General |
| Non-linearity |
±0.1% @ in % full scale |
| Capacitive load, max |
0.1 µF @ voltage outputs |
| Inductive load, max |
0.01 mH @ current outputs |
| Open and short-circuit protection |
True |
| Recommended maximum shielded cable length |
10 m |
| Step response to 63% |
5 ms |
| I/O Status Indication |
None |
| Not published by the manufacturer — 待原厂规格书核定 |
| Supply voltage |
待原厂规格书核定 |
| I/O and communication |
待原厂规格书核定 |
| Mounting |
待原厂规格书核定 |
| Enclosure rating |
待原厂规格书核定 |
| Certifications |
待原厂规格书核定 |
Values above are copied verbatim from the manufacturer product page (https://www.rockwellautomation.com/en-us/products/details.2080-of2.html) or the manufacturer technical data publication. Fields listed with the value 待原厂规格书核定 are not published by the manufacturer for this catalog number: the field name is kept, no value is estimated, and the original manufacturer data sheet is required before use.
Selection notes for Allen-Bradley 2080-OF2
- Mounting torque: 0.2 nm — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
- Shock: IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
- Terminal screw torque: 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver) — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
- Vibration: IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
- Load range on voltage output: > 1k Ω @ 10V DC — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
Available from stock with datasheet, certificates and a quotation on request.
Common questions about 2080-OF2
Q.What specification value does the manufacturer publish for 2080-OF2?
For 2080-OF2 The manufacturer product page publishes mounting torque = 0.2 nm. Confirm the revision of the installed unit if the catalog number has been superseded.
Q.What specification value does the manufacturer publish for 2080-OF2?
For 2080-OF2 The manufacturer product page publishes shock = IEC 60068-2-27 (Test Ea, unpackaged shock): DIN rail mount: 25 g, nonoperating, Panel Mount: 35 g nonoperating. Confirm the revision of the installed unit if the catalog number has been superseded.
Q.What specification value does the manufacturer publish for 2080-OF2?
For 2080-OF2 The manufacturer product page publishes terminal screw torque = 0.22...0.25 Nm (1.95...2.21 in-lb) (using a 2.5 mm (0.10 in.) flat-blade screwdriver). Confirm the revision of the installed unit if the catalog number has been superseded.
Q.What specification value does the manufacturer publish for 2080-OF2?
For 2080-OF2 The manufacturer product page publishes vibration = IEC 60068-2-6 (Test Fc, operating), 2 G @ 10...500 Hz. Confirm the revision of the installed unit if the catalog number has been superseded.
Q.How do I confirm compatibility of 2080-OF2 before ordering?
Match the catalog number 2080-OF2 and the specification values above against the nameplate of the installed unit, and confirm the firmware or hardware revision where a revision-sensitive part is involved.