Allen-Bradley 1756-TIME ControlLogix Time Synchronization Module

SKU: 1756-TIME
Regular price $8,999.00
In stock (88 units)
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

Allen-Bradley · 1756-TIME

1756-TIME is an Allen-Bradley 1756-TIME — ControlLogix Position and Time Services. Official specification values published for this catalog number: 1403-CFxxx Rockwell Automation fiber-optic cable assembly (官方数据表 1756-TD003K p.36);HCP-M0200T V01RK Lucent Technologies 200 μm simplex cable (官方数据表 1756-TD003K p.36);Conducted RF Immunity ; IEC 61000-4-6 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz (官方数据表 1756-TD003K p.37).

  • 1403-CFxxxRockwell Automation fiber-optic cable assembly (官方数据表 1756-TD003K p.36)
  • HCP-M0200T V01RKLucent Technologies 200 μm simplex cable (官方数据表 1756-TD003K p.36)
  • Conducted RF Immunity ; IEC 61000-4-610V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz (官方数据表 1756-TD003K p.37)
  • EDS Immunity ; IEC 61000-4-24 kV contact discharges ; 8 kV air discharges (官方数据表 1756-TD003K p.37)

Specifications

Electrical
Isolation voltage 30V (continuous), Basic Insulation Type ; Type tested at 1000V AC for 60 s ; • Ethernet Ports to Backplane ; • IRIG-B to Backplane (官方数据表 1756-TD003K p.37)
Voltage and current ratings Backplane: 1.01A @ 5.1V DC, 2.64 mA @ 1.2 V DC (官方数据表 1756-TD003K p.37)
Wire size Ethernet connections ; • RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 ; or Category 5 cable according to ISO/IEC 24702 ; IRIG-B connection ; • Type RG58 or equivalent ; Antenna connection ; • Cable assembly, TNC Plug to SMA, ships with product (官方数据表 1756-TD003K p.37)
Wiring Category(1) • 2 - on signal ports ; • 2 - on communications ports (官方数据表 1756-TD003K p.37)
Mechanical
Enclosure type rating None (open-style) (官方数据表 1756-TD003K p.37)
Environment and compliance
Conducted RF Immunity ; IEC 61000-4-6 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz (官方数据表 1756-TD003K p.37)
EDS Immunity ; IEC 61000-4-2 4 kV contact discharges ; 8 kV air discharges (官方数据表 1756-TD003K p.37)
EFT/B Immunity ; IEC 61000-4-4 ±2 kV at 5 kHz on signal ports ; ±2 kV at 5 kHz on communications ports (官方数据表 1756-TD003K p.37)
Emissions IEC 61000-6-4 (官方数据表 1756-TD003K p.37)
Radiated RF Immunity ; IEC 61000-4-3 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz ; 10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz ; 10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz ; 3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz ; 3V/m with 1 kHz sine-wave 80% AM from 2700…6000 MHz (官方数据表 1756-TD003K p.37)
Relative humidity ; IEC 60068-2-30 (Test Db, Unpackaged Damp Heat) 5…95% noncondensing (官方数据表 1756-TD003K p.37)
Surge Transient Immunity ; IEC 61000-4-5 ±2 kV line-earth(CM) on signal ports ; no shielded ports - omit from publication ; ±2 kV line-earth(CM) on communications ports (官方数据表 1756-TD003K p.37)
Temperature, surrounding air, max +50 °C (+122 °F) in a Series B Chassis ; +60 °C (+140 °F) in a Series C Chassis (官方数据表 1756-TD003K p.37)
General
1403-CFxxx Rockwell Automation fiber-optic cable assembly (官方数据表 1756-TD003K p.36)
HCP-M0200T V01RK Lucent Technologies 200 μm simplex cable (官方数据表 1756-TD003K p.36)
Antenna SMA connector Connect the GPS bullet antenna to this connector. See GPS Antenna on page 9. (官方数据表 1756-UM542 p.8)
Hardware Description (官方数据表 1756-UM542 p.8)
IRIG-B BNC type connector Connect the IRIG-B network cable to this connector. The 1756-TIME module ; can be configured as a master clock or a slave clock on the IRIG-B network. (官方数据表 1756-UM542 p.8)
Status indicators and messages Provides status and operational information for the 1756-TIME module. ; See 1756-TIME Module Status Indicators on page 41. (官方数据表 1756-UM542 p.8)
OK Green = the module has started successfully. ; Red = the module has a hardware fault. (官方数据表 1756-UM542 p.41)
PPS This indicator is toggled every second for 100 ms at the exact PPS. ; Green = the module is locked on the time source. ; Red = the module is not locked on the time source. ; When the module is set to be an IRIG-IN or slave clock, this indicator is toggled every ; time a reference frame is received. (官方数据表 1756-UM542 p.41)
SYNC Green = the module is locked on the time source. ; Red = the module is not locked on the time source. (官方数据表 1756-UM542 p.41)
Status Indicators Description (官方数据表 1756-UM542 p.41)
Cable Type Typical Attenuation Values in dB (官方数据表 1756-UM542 p.49)
RG58 3.1 / 6.3 / 9.4 / 12.5 / 15.7 / 18.8 / 21.9 / 25.0 / 28.2 / 31.3 / 34.4 / 37.6 / 40.7 / 43.8 / 47.0 / 50.1 / 53.2 / 56.3 / 59.5 / 62.6 (官方数据表 1756-UM542 p.49)
LMR-240 1.6 / 3.2 / 4.9 / 6.5 / 8.1 / 9.7 / 11.3 / 13.0 / 14.6 / 16.2 / 17.8 / 19.4 / 21.0 / 22.7 / 24.3 / 25.9 / 27.5 / 29.1 / 30.8 / 32.4 (官方数据表 1756-UM542 p.50)
LMR-400 0.8 / 1.7 / 2.5 / 3.4 / 4.2 / 5.0 / 5.9 / 6.7 / 7.6 / 8.4 / 9.2 / 10.1 / 10.9 / 11.8 / 12.6 / 13.5 / 14.3 / 15.1 / 16.0 / 16.8 (官方数据表 1756-UM542 p.50)
LMR-600 0.5 / 1.1 / 1.6 / 2.2 / 2.7 / 3.3 / 3.8 / 4.4 / 4.9 / 5.4 / 6.0 / 6.5 / 7.1 / 7.6 / 8.2 / 8.7 / 9.2 / 9.8 / 10.3 / 10.9 (官方数据表 1756-UM542 p.50)

Values above are copied verbatim from the manufacturer product page (https://qa-aem.rockwellautomation.com/en-gb/products/details.1756-TIME.html); values marked with an official data sheet reference are taken from the manufacturer technical data publication cited with the page number. Fields the manufacturer does not publish for this catalog number are not listed here and must be confirmed against the original data sheet before use.

Selection notes for Allen-Bradley 1756-TIME

  • 1403-CFxxx: Rockwell Automation fiber-optic cable assembly (官方数据表 1756-TD003K p.36) — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
  • HCP-M0200T V01RK: Lucent Technologies 200 μm simplex cable (官方数据表 1756-TD003K p.36) — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
  • Conducted RF Immunity ; IEC 61000-4-6: 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz (官方数据表 1756-TD003K p.37) — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
  • EDS Immunity ; IEC 61000-4-2: 4 kV contact discharges ; 8 kV air discharges (官方数据表 1756-TD003K p.37) — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.
  • EFT/B Immunity ; IEC 61000-4-4: ±2 kV at 5 kHz on signal ports ; ±2 kV at 5 kHz on communications ports (官方数据表 1756-TD003K p.37) — as published on the manufacturer product page; confirm the revision of the installed unit before specifying a like-for-like replacement.

Available from stock with datasheet, certificates and a quotation on request.

Common questions about 1756-TIME

Q.What specification value does the manufacturer publish for 1756-TIME?

For 1756-TIME the manufacturer product page publishes 1403-cfxxx = Rockwell Automation fiber-optic cable assembly (官方数据表 1756-TD003K p.36). Confirm the revision of the installed unit if the catalog number has been superseded.

Q.What specification value does the manufacturer publish for 1756-TIME?

For 1756-TIME the manufacturer product page publishes hcp-m0200t v01rk = Lucent Technologies 200 μm simplex cable (官方数据表 1756-TD003K p.36). Confirm the revision of the installed unit if the catalog number has been superseded.

Q.What specification value does the manufacturer publish for 1756-TIME?

For 1756-TIME the manufacturer product page publishes conducted rf immunity ; iec 61000-4-6 = 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz (官方数据表 1756-TD003K p.37). Confirm the revision of the installed unit if the catalog number has been superseded.

Q.What specification value does the manufacturer publish for 1756-TIME?

For 1756-TIME the manufacturer product page publishes eds immunity ; iec 61000-4-2 = 4 kV contact discharges ; 8 kV air discharges (官方数据表 1756-TD003K p.37). Confirm the revision of the installed unit if the catalog number has been superseded.

Q.How do I confirm compatibility of 1756-TIME before ordering?

Match the catalog number 1756-TIME and the specification values above against the nameplate of the installed unit, and confirm the firmware or hardware revision where a revision-sensitive part is involved.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!