Allen-Bradley 140M-C2E-C16 Circuit Breaker – 16 A

SKU: 140M-C2E-C16
Regular price $69.98
In stock (88 units)
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

Allen-Bradley · circuit breaker

140M-C2E-C16 is an Allen-Bradley circuit breaker with Tripping characteristic B / C / D (IEC 60947-2); Number of poles 1 / 2 / 3 / 4 (IEC 60947-2); Rated operational voltage <= 440 V AC. It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Tripping characteristicB / C / D (IEC 60947-2)
  • Number of poles1 / 2 / 3 / 4 (IEC 60947-2)
  • Rated operational voltage<= 440 V AC
  • Breaking capacity Icu/Ics6 kA / 10 kA (IEC 60947-2)

Specifications

Electrical
Rated operational voltage <= 440 V AC
Rated insulation voltage Ui 440 V (IEC 60947-2)
Rated impulse withstand Uimp 4 kV (IEC 60947-2)
Breaking capacity Icu/Ics 6 kA / 10 kA (IEC 60947-2)
Tripping characteristic B / C / D (IEC 60947-2)
Number of poles 1 / 2 / 3 / 4 (IEC 60947-2)
Mechanical
Mounting 35 mm DIN rail (IEC 60715)
Enclosure rating IP20 (IEC 60529)
Environment and compliance
Operating temperature -25...+60 °C
Certifications CE, UL, cULus

Values follow the Allen-Bradley circuit breaker specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

Allen-Bradley circuit breaker variants
Catalog number Tripping characteristic Breaking capacity Icu/Ics Rated operational voltage
140M-C2E-C16 (this page) B / C / D (IEC 60947-2) 6 kA / 10 kA (IEC 60947-2) <= 440 V AC
140M-C2E-C10 B / C / D (IEC 60947-2) 6 kA / 10 kA (IEC 60947-2) <= 440 V AC
140M-F8N-C32 B / C / D (IEC 60947-2) 6 kA / 10 kA (IEC 60947-2) <= 440 V AC
1489-M1C010 B / C / D (IEC 60947-2) 6 kA / 10 kA (IEC 60947-2) <= 440 V AC

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The 140M-C2E-C16 is the device-level element in an Allen-Bradley circuit breaker installation. It receives the field signals and control supply listed above — <= 440 V AC — and switches or conditions the load within the <= 440 V AC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for Allen-Bradley 140M-C2E-C16

Allen-Bradley 140M-C2E-C16 — Circuit breaker providing branch-circuit overload and short-circuit protection in distribution boards and panel feeders. The figures below are taken from the specification table on this page for catalog number 140M-C2E-C16; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.

  • Mounting: 35 mm DIN rail (IEC 60715) — Use it as the reference when cross-checking a current-production equivalent.
  • Rated operational voltage: <= 440 V AC — Verify it in the project documentation before confirming the order.
  • Number of poles: 1 / 2 / 3 / 4 (IEC 60947-2) — Check this value against the nameplate of the installed unit before ordering.
  • Breaking capacity Icu/Ics: 6 kA / 10 kA (IEC 60947-2) — Match it to the existing panel and upstream protection.

Cross-check the ratings above with the installed device before confirming the order.

Common questions about 140M-C2E-C16

Q.For 140M-C2E-C16, what does the specification table state about mounting?

The specification table lists mounting = 35 mm DIN rail (IEC 60715) for Allen-Bradley 140M-C2E-C16. Compare it with the nameplate of the installed unit before ordering.

Q.Which value is published under enclosure rating for catalog number 140M-C2E-C16?

For 140M-C2E-C16, enclosure rating is given as IP20 (IEC 60529). Confirm this figure against the unit currently in the panel.

Q.Before ordering 140M-C2E-C16, which rated insulation voltage Ui entry should be checked?

The rated insulation voltage Ui entry quoted above is 440 V (IEC 60947-2). Use the value as the reference when sourcing a current-production equivalent.

Q.How do I confirm compatibility of 140M-C2E-C16 before ordering?

Match the catalog number 140M-C2E-C16 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Q.Can the 140M-C2E-C16 replace the unit currently installed in my panel?

Compare catalog number 140M-C2E-C16 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!