Technical parameters compiled from the manufacturer data sheet and reference documentation.
| Technical Specifications |
| Type Designation |
| Auxiliary circuits/overvoltage category-inv |
6kV/III @ rated impulse withstand voltage (Uimp) |
| Short circuit current (Type 2 coordination), max-inv |
50kA @ 400V |
| Type of control element |
Turn button |
| Type of electrical connection of main circuit |
Screw connection |
| Contactor size (Type 2 coordination), min-inv |
100-C30 @ 600V |
| Protection type |
Adjustable thermal/fixed magnetic (13 x In) |
| Power Supply |
| Phase failure sensitive |
True |
| Phase loss protection |
Differential release |
| Rated frequency |
50/60 Hz |
| Rated operating voltage |
230 A |
| Rated operating voltage, max |
690V per IEC, SEV, VDE0660 |
| Rated supply current |
0.1 A |
| Switching frequency, max |
25 ops/h |
| Total power loss (Pv) for circuit breaker at rated load operating temperature-inv |
6 W |
| Mechanical |
| Short circuit current for tap conductor protection, max |
30 kA @ 480Y/277V per UL 508-manual motor controller |
| Depth |
74.5 mm |
| Height |
90 mm |
| Width |
45 mm |
| Degree of protection (IP) |
IP2X |
| Weight |
317 lb |
| Environmental |
| Ambient operating temperature |
-25 °C |
| Ambient storage temperature |
-40 °C |
| Ambient temperature compensation |
-20 °C |
| Dependence on temperature |
No current reduction @ 60 °C-inv |
| Site altitude |
To 2000 N.N.(m) |
| Compliance, Approvals & Standards |
| Rated service short circuit breaking capacity (Ics) per IEC |
6kA @ 500V |
| Device construction |
Built-in device fixed built-in technique |
| Other |
| Application |
Mtr Prt Circuit Breaker |
| Back up fuse (gG, gL) current rating (if Icc ≥ Icu ) per IEC |
No back-up fuse required @ 230/240V |
| Current range |
10...16 A |
| Electrical life cycle |
(Ie max.) 100000 ops |
| Fuse or circuit breaker per NEC, max |
450 A, UL 508-manual motor controller |
| Fuse or circuit breaker rating per NEC, max |
450 A, UL 508-manual motor controller with 100-C contactor |
| Hp rating, max |
5Hp @ 230V, 3-phase |
| Magnetic release current per IEC |
208 A |
| Number of poles |
3 |
| Overload release current setting |
10 A |
| Rated operational current (Ie) per IEC |
16 A |
| Short circuit current for combination motor controller, max |
30kA @ 480V/277V per UL 508-self-protected (Type E) |
| Short circuit current for group motor installation with 100-C contactor, max-inv |
30kA @ 600V, UL 508-manual motor controller |
| Short circuit current for motor disconnect with 100-C contactor, max-inv |
30kA @ 480V, UL 508-manual motor controller |
| Switch off technique |
Thermomagnetic |
| Trip class |
10 |
| Ultimate short circuit breaking capacity (Icu) per IEC |
65kA @ 400/415V |
| With integrated auxiliary switch |
False |
| Contactor size, min-inv |
100-K12: UL-508-Type F combination motor controller |
| Frame size |
Frame size C, 32 A |
| Factory option |
No circuit-breaker auxiliary or trip contacts |
| Mechanical life operations |
100000 /h |
| 140m-td002_-en-p |
140M-TD002 |
| C-Frame |
D-Frame |
| Code |
Description |
| 8 |
High Break |
| 14.5…20 |
140M-C2E-C20 |
| 18…25 |
140M-C2E-C25 |
| 24…29 |
140M-C2E-C29 |
| 27…32 |
140M-C2E-C32 |
| Cat.No. |
140M-RC… |
| 1.conductor 2.conductor |
[mm2]/[AWG] [mm2]/[AWG] |
Model variants, options and firmware revisions can affect fitment. Before ordering the Allen-Bradley 140M-C2E-C16 motor protection circuit breaker, share your existing part number or project requirements and our team will cross-reference comparable in-stock Allen-Bradley units and verify compatibility. This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for identification only.
Independent supplier: Allen-Bradley part 140M-C2E-C16 is supplied by SHLY-PLC, an independent industrial-automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.
A: Each 140M-C2E-C16 is inspected and functionally checked before sale. Contact us for the current stock condition and quantity.
A: In-stock orders placed before 14:00 ship the same business day. Standard worldwide delivery is about 5-8 business days, express shipping is available and orders over $500 ship free.
A: Yes. Share your existing part number or application and our technical team will verify compatibility and provide cross-references to comparable in-stock models.