Phoenix Contact · Temperature Transmitter
2905577 is a Phoenix Contact industrial component with Supply voltage 11...30 V DC (loop powered); Enclosure rating IP66 / IP67 (IEC 60529); Operating temperature -40...+85 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltage11...30 V DC (loop powered)
-
Enclosure ratingIP66 / IP67 (IEC 60529)
-
Operating temperature-40...+85 °C (IEC 60068-2-1)
-
MountingDIN rail mounting
Specifications
| Electrical |
| Rated insulation voltage Ui |
50 V AC/DC |
| Tripping characteristic |
12 mm |
| Supply voltage |
11...30 V DC (loop powered) |
| Frequency |
> 175 Hz |
| I/O and communication |
| Protocols |
HART |
| Mechanical |
| Weight |
62.2 g |
| Mounting |
DIN rail mounting |
| Terminal wire size |
0.2 mm² ... 2.5 mm² |
| Enclosure rating |
IP66 / IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-40...+85 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
| Humidity |
5 % ... 95 % (non-condensing) |
Values follow the Phoenix Contact Temperature Transmitter specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Temperature Transmitter variants |
| Catalog number |
Mounting |
|
2905577 (this page) |
DIN rail mounting |
| 2905026 |
DIN rail mounting |
| 2905249 |
DIN rail mounting |
| 2902000 |
DIN rail mounting |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 2905577 is the device-level element in a Phoenix Contact industrial component installation. It receives the field signals and control supply listed above — 11...30 V DC (loop powered) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail mounting support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 2905577
Phoenix Contact 2905577 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 2905577; always cross-check the catalog number and hardware revision on the nameplate before placing an order.
- Frequency: > 175 Hz — Verify it in the project documentation before confirming the order.
- Humidity: 5 % ... 95 % (non-condensing) — Check this value against the nameplate of the installed unit before ordering.
- Certifications: CE, UL, cULus — Match it to the existing panel and upstream protection.
- Protocols: HART — Record it with the other nameplate data when sourcing a replacement.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about 2905577
Q.Where can I find the weight data for 2905577?
It is listed in the specification table for Phoenix Contact 2905577 as 62.2 g. Compare it with the nameplate of the installed unit before ordering.
Q.For 2905577, what does the specification table state about operating temperature?
The specification table lists operating temperature = -40...+85 °C (IEC 60068-2-1) for Phoenix Contact 2905577. Confirm this figure against the unit currently in the panel.
Q.Which value is published under protocols for catalog number 2905577?
For 2905577, protocols is given as HART. Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for 2905577?
Send the full catalog number 2905577, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 2905577.
Q.Can the 2905577 replace the unit currently installed in my panel?
Compare catalog number 2905577 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.