SICK WLL180T-M Fiber-optic photoelectric amplifier

SKU: WLL180T-M
Regular price $53.94
In stock (69 units)
Condition
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

SICK · Photoelectric Sensor

WLL180T-M is a SICK limit switch with Rated operational voltage 240 V AC / 250 V DC; Supply voltage 12 ... 24 V DC 4); Enclosure rating IP65 / IP67 (IEC 60529). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Rated operational voltage240 V AC / 250 V DC
  • Supply voltage12 ... 24 V DC 4)
  • Enclosure ratingIP65 / IP67 (IEC 60529)
  • Operating temperature-25...+70 °C (IEC 60068-2-1)

Specifications

Electrical
Rated operational voltage 240 V AC / 250 V DC
Supply voltage 12 ... 24 V DC 4)
Output current ≤ 100 mA
Power consumption ≤ 50 mA 6)
Frequency 31.2 kHz/7.1 kHz/2 kHz/250 Hz/62.5 Hz
Mechanical
Weight Approx. 25 g
Mounting Through body / bracket
Enclosure rating IP65 / IP67 (IEC 60529)
Environment and compliance
Operating temperature -25...+70 °C (IEC 60068-2-1)
Certifications CE, cULus

Values follow the SICK Photoelectric Sensor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

SICK Photoelectric Sensor variants
Catalog number Rated operational voltage Mounting
WLL180T-M (this page) 240 V AC / 250 V DC Through body / bracket
WLL180T-M434 240 V AC / 250 V DC Through body / bracket
WLL180T-F434 240 V AC / 250 V DC Through body / bracket
WLL180T-F434S05 240 V AC / 250 V DC Through body / bracket

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The WLL180T-M is the device-level element in a SICK limit switch installation. It receives the field signals and control supply listed above — 12 ... 24 V DC 4) — and switches or conditions the load within the 240 V AC / 250 V DC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides Through body / bracket support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for SICK WLL180T-M

SICK WLL180T-M — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number WLL180T-M; record the nameplate data of the unit being replaced before selecting an equivalent.

  • Operating temperature: -25...+70 °C (IEC 60068-2-1) — Record it with the other nameplate data when sourcing a replacement.
  • Rated operational voltage: 240 V AC / 250 V DC — Confirm the revision of the installed unit before a like-for-like replacement.
  • Power consumption: ≤ 50 mA 6) — Use it as the reference when cross-checking a current-production equivalent.
  • Frequency: 31.2 kHz/7.1 kHz/2 kHz/250 Hz/62.5 Hz — Verify it in the project documentation before confirming the order.

Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.

Common questions about WLL180T-M

Q.Before ordering WLL180T-M, which rated operational voltage entry should be checked?

The rated operational voltage entry quoted above is 240 V AC / 250 V DC. Compare it with the nameplate of the installed unit before ordering.

Q.Where can I find the frequency data for WLL180T-M?

It is listed in the specification table for SICK WLL180T-M as 31.2 kHz/7.1 kHz/2 kHz/250 Hz/62.5 Hz. Confirm this figure against the unit currently in the panel.

Q.For WLL180T-M, what does the specification table state about enclosure rating?

The specification table lists enclosure rating = IP65 / IP67 (IEC 60529) for SICK WLL180T-M. Use the value as the reference when sourcing a current-production equivalent.

Q.What should I include in an enquiry for WLL180T-M?

Send the full catalog number WLL180T-M, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for SICK WLL180T-M.

Q.Can the WLL180T-M replace the unit currently installed in my panel?

Compare catalog number WLL180T-M and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!