SICK · Photoelectric Sensor
WLL180T-M is a SICK limit switch with Rated operational voltage 240 V AC / 250 V DC; Supply voltage 12 ... 24 V DC 4); Enclosure rating IP65 / IP67 (IEC 60529). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated operational voltage240 V AC / 250 V DC
-
Supply voltage12 ... 24 V DC 4)
-
Enclosure ratingIP65 / IP67 (IEC 60529)
-
Operating temperature-25...+70 °C (IEC 60068-2-1)
Specifications
| Electrical |
| Rated operational voltage |
240 V AC / 250 V DC |
| Supply voltage |
12 ... 24 V DC 4) |
| Output current |
≤ 100 mA |
| Power consumption |
≤ 50 mA 6) |
| Frequency |
31.2 kHz/7.1 kHz/2 kHz/250 Hz/62.5 Hz |
| Mechanical |
| Weight |
Approx. 25 g |
| Mounting |
Through body / bracket |
| Enclosure rating |
IP65 / IP67 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the SICK Photoelectric Sensor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| SICK Photoelectric Sensor variants |
| Catalog number |
Rated operational voltage |
Mounting |
|
WLL180T-M (this page) |
240 V AC / 250 V DC |
Through body / bracket |
| WLL180T-M434 |
240 V AC / 250 V DC |
Through body / bracket |
| WLL180T-F434 |
240 V AC / 250 V DC |
Through body / bracket |
| WLL180T-F434S05 |
240 V AC / 250 V DC |
Through body / bracket |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The WLL180T-M is the device-level element in a SICK limit switch installation. It receives the field signals and control supply listed above — 12 ... 24 V DC 4) — and switches or conditions the load within the 240 V AC / 250 V DC ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides Through body / bracket support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for SICK WLL180T-M
SICK WLL180T-M — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number WLL180T-M; record the nameplate data of the unit being replaced before selecting an equivalent.
- Operating temperature: -25...+70 °C (IEC 60068-2-1) — Record it with the other nameplate data when sourcing a replacement.
- Rated operational voltage: 240 V AC / 250 V DC — Confirm the revision of the installed unit before a like-for-like replacement.
- Power consumption: ≤ 50 mA 6) — Use it as the reference when cross-checking a current-production equivalent.
- Frequency: 31.2 kHz/7.1 kHz/2 kHz/250 Hz/62.5 Hz — Verify it in the project documentation before confirming the order.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about WLL180T-M
Q.Before ordering WLL180T-M, which rated operational voltage entry should be checked?
The rated operational voltage entry quoted above is 240 V AC / 250 V DC. Compare it with the nameplate of the installed unit before ordering.
Q.Where can I find the frequency data for WLL180T-M?
It is listed in the specification table for SICK WLL180T-M as 31.2 kHz/7.1 kHz/2 kHz/250 Hz/62.5 Hz. Confirm this figure against the unit currently in the panel.
Q.For WLL180T-M, what does the specification table state about enclosure rating?
The specification table lists enclosure rating = IP65 / IP67 (IEC 60529) for SICK WLL180T-M. Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for WLL180T-M?
Send the full catalog number WLL180T-M, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for SICK WLL180T-M.
Q.Can the WLL180T-M replace the unit currently installed in my panel?
Compare catalog number WLL180T-M and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.