SICK WL121-3P1731 Photoelectric retro-reflective sensor

SKU: WL121-3P1731
Regular price $564.30
In stock (55 units)
Free standard shipping on orders of $500 and above
100% secure payments
Industry leading quality

SICK · Photoelectric sensor

WL121-3P1731 is a SICK photoelectric sensor with Output type (PNP/NPN) PNP/NPN (depending on type); Supply voltage 10...30 V DC (IEC 60947-5-2); Enclosure rating IP67 (IEC 60529). It is used in conveyor object detection, machine guarding, position feedback where the installed unit is matched to the original catalog number and a compact, documented part is required.

  • Output type (PNP/NPN)PNP/NPN (depending on type)
  • Supply voltage10...30 V DC (IEC 60947-5-2)
  • Enclosure ratingIP67 (IEC 60529)
  • Response time<= 1000 Hz switching frequency

Specifications

Electrical
Supply voltage 10...30 V DC (IEC 60947-5-2)
Output current 100 mA
Power consumption ≤ 15 mA ... ≤ 25 mA
I/O and communication
Response time <= 1000 Hz switching frequency
Output type (PNP/NPN) PNP/NPN (depending on type)
Mechanical
Dimensions (H x W x D) 15.6 mm x 48.5 mm x 42 mm
Enclosure rating IP67 (IEC 60529)
Environment and compliance
Operating temperature -25...+70 °C (IEC 60068-2-1)
Certifications CE, cULus

Values follow the SICK Photoelectric sensor specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.

Model comparison in the same family

SICK Photoelectric sensor variants
Catalog number Output type (PNP/NPN) Supply voltage
WL121-3P1731 (this page) PNP/NPN (depending on type) 10...30 V DC (IEC 60947-5-2)
WL12-2N120 PNP 10...30 V DC (IEC 60947-5-2)
WL100-2N3439 — DC 10 V ... 30 V
WL100-2P1409S31 — DC 10 V ... 30 V

Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.

Where it sits in the control system

The WL121-3P1731 is the device-level element in a SICK photoelectric sensor installation. It receives the field signals and control supply listed above — 10...30 V DC (IEC 60947-5-2) — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.

Typical installations place it in conveyor object detection, machine guarding, position feedback, where the unit is matched to the original catalog number and the enclosure provides standard panel or DIN-rail support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.

Selection notes for SICK WL121-3P1731

SICK WL121-3P1731 — Sensor or detector for object detection, distance measurement and status feedback on production lines. The figures below are taken from the specification table on this page for catalog number WL121-3P1731; size the surrounding wiring and upstream protection to these published ratings rather than to a generic assumption.

  • Enclosure rating: IP67 (IEC 60529) — Record it with the other nameplate data when sourcing a replacement.
  • Operating temperature: -25...+70 °C (IEC 60068-2-1) — Confirm the revision of the installed unit before a like-for-like replacement.
  • Certifications: CE, cULus — Use it as the reference when cross-checking a current-production equivalent.
  • Supply voltage: 10...30 V DC (IEC 60947-5-2) — Verify it in the project documentation before confirming the order.

For a discontinued unit, match function and electrical ratings rather than the label alone.

Common questions about WL121-3P1731

Q.Before ordering WL121-3P1731, which operating temperature entry should be checked?

The operating temperature entry quoted above is -25...+70 °C (IEC 60068-2-1). Compare it with the nameplate of the installed unit before ordering.

Q.Where can I find the certifications data for WL121-3P1731?

It is listed in the specification table for SICK WL121-3P1731 as CE, cULus. Confirm this figure against the unit currently in the panel.

Q.For WL121-3P1731, what does the specification table state about dimensions (H x W x D)?

The specification table lists dimensions (H x W x D) = 15.6 mm x 48.5 mm x 42 mm for SICK WL121-3P1731. Use the value as the reference when sourcing a current-production equivalent.

Q.Can the WL121-3P1731 replace the unit currently installed in my panel?

Compare catalog number WL121-3P1731 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.

Q.How do I confirm compatibility of WL121-3P1731 before ordering?

Match the catalog number WL121-3P1731 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.

Standard (US & Canada, tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders under $500.00; free on orders of $500.00 and above.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Shipping charges and available services are displayed at checkout. See the Shipping Policy for details.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!