SICK · Safety controller
UE440-A0410 is a SICK industrial component with Supply voltage DC 24 V; Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Supply voltageDC 24 V
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
Specifications
| Electrical |
| Rated insulation voltage Ui |
690 V (IEC 60947-4-1) |
| Rated impulse withstand Uimp |
6 kV (IEC 60947-4-1) |
| Supply voltage |
DC 24 V |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the SICK Safety controller specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| SICK Safety controller variants |
| Catalog number |
Mounting |
|
UE440-A0410 (this page) |
DIN rail / panel |
| UE44-3SL3D33 |
DIN rail / panel |
| UE44-3SL3D330 |
DIN rail / panel |
| UE410-2RO4 |
35 mm DIN rail (IEC 60715) |
Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.
Where it sits in the control system
The UE440-A0410 is the device-level element in a SICK industrial component installation. It receives the field signals and control supply listed above — DC 24 V — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for SICK UE440-A0410
SICK UE440-A0410 Safety Controller. See the manufacturer product information for this catalog number.
- Supply voltage: DC 24 V — Record it with the other nameplate data when sourcing a replacement.
- Operating temperature: 0...+55 °C (IEC 60068-2-1) — Confirm the revision of the installed unit before a like-for-like replacement.
- Certifications: CE, cULus — Use it as the reference when cross-checking a current-production equivalent.
- Rated insulation voltage Ui: 690 V (IEC 60947-4-1) — Verify it in the project documentation before confirming the order.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about UE440-A0410
Q.Where can I find the supply voltage data for UE440-A0410?
It is listed in the specification table for SICK UE440-A0410 as DC 24 V. Compare it with the nameplate of the installed unit before ordering.
Q.For UE440-A0410, what does the specification table state about mounting?
The specification table lists mounting = DIN rail / panel for SICK UE440-A0410. Confirm this figure against the unit currently in the panel.
Q.Which value is published under rated insulation voltage Ui for catalog number UE440-A0410?
For UE440-A0410, rated insulation voltage Ui is given as 690 V (IEC 60947-4-1). Use the value as the reference when sourcing a current-production equivalent.
Q.What should I include in an enquiry for UE440-A0410?
Send the full catalog number UE440-A0410, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for SICK UE440-A0410.
Q.How do I confirm compatibility of UE440-A0410 before ordering?
Match the catalog number UE440-A0410 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.