SICK · Safety controller
UE44-3SL3D33 is a SICK industrial component with Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1); Mounting DIN rail / panel. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
-
CertificationsCE, cULus
Specifications
| Electrical |
| Rated insulation voltage Ui |
690 V (IEC 60947-4-1) |
| Rated impulse withstand Uimp |
6 kV (IEC 60947-4-1) |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the SICK Safety controller specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| SICK Safety controller variants |
| Catalog number |
Mounting |
|
UE44-3SL3D33 (this page) |
DIN rail / panel |
| UE44-3SL3D330 |
DIN rail / panel |
| UE440-A0410 |
DIN rail / panel |
| UE410-2RO4 |
35 mm DIN rail (IEC 60715) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The UE44-3SL3D33 is the device-level element in a SICK industrial component installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for SICK UE44-3SL3D33
SICK UE44-3SL3D33 Safety Relay. See the manufacturer documentation for this order number.
- Rated impulse withstand Uimp: 6 kV (IEC 60947-4-1) — Use it as the reference when cross-checking a current-production equivalent.
- Enclosure rating: IP20 (IEC 60529) — Verify it in the project documentation before confirming the order.
- Rated insulation voltage Ui: 690 V (IEC 60947-4-1) — Check this value against the nameplate of the installed unit before ordering.
- Mounting: DIN rail / panel — Match it to the existing panel and upstream protection.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about UE44-3SL3D33
Q.Which value is published under operating temperature for catalog number UE44-3SL3D33?
For UE44-3SL3D33, operating temperature is given as 0...+55 °C (IEC 60068-2-1). Compare it with the nameplate of the installed unit before ordering.
Q.Before ordering UE44-3SL3D33, which certifications entry should be checked?
The certifications entry quoted above is CE, cULus. Confirm this figure against the unit currently in the panel.
Q.Where can I find the rated insulation voltage Ui data for UE44-3SL3D33?
It is listed in the specification table for SICK UE44-3SL3D33 as 690 V (IEC 60947-4-1). Use the value as the reference when sourcing a current-production equivalent.
Q.How do I confirm compatibility of UE44-3SL3D33 before ordering?
Match the catalog number UE44-3SL3D33 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the UE44-3SL3D33 replace the unit currently installed in my panel?
Compare catalog number UE44-3SL3D33 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.