SICK · Safety controller
UE43-4AR2D2 is a SICK industrial component with Enclosure rating IP20 (IEC 60529); Operating temperature 0...+55 °C (IEC 60068-2-1); Mounting DIN rail / panel. It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Enclosure ratingIP20 (IEC 60529)
-
Operating temperature0...+55 °C (IEC 60068-2-1)
-
MountingDIN rail / panel
-
CertificationsCE, cULus
Specifications
| Electrical |
| Rated insulation voltage Ui |
690 V (IEC 60947-4-1) |
| Rated impulse withstand Uimp |
6 kV (IEC 60947-4-1) |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
0...+55 °C (IEC 60068-2-1) |
| Certifications |
CE, cULus |
Values follow the SICK Safety controller specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| SICK Safety controller variants |
| Catalog number |
Mounting |
|
UE43-4AR2D2 (this page) |
DIN rail / panel |
| UE43-3MF |
DIN rail / panel |
| UE43-3MF2A2 |
DIN rail / panel |
| UE43-3MF2A3 |
DIN rail / panel |
Verify model-specific dimensions, terminals and installation requirements in the manufacturer documentation before selecting an alternative.
Where it sits in the control system
The UE43-4AR2D2 is the device-level element in a SICK industrial component installation. It receives the field signals and control supply listed above — the rated supply — and switches or conditions the load within the the rated ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for SICK UE43-4AR2D2
SICK UE43-4AR2D2 Safety Relay. See the manufacturer product information for this catalog number.
- Certifications: CE, cULus — Confirm the revision of the installed unit before a like-for-like replacement.
- Rated insulation voltage Ui: 690 V (IEC 60947-4-1) — Use it as the reference when cross-checking a current-production equivalent.
- Rated impulse withstand Uimp: 6 kV (IEC 60947-4-1) — Verify it in the project documentation before confirming the order.
- Operating temperature: 0...+55 °C (IEC 60068-2-1) — Check this value against the nameplate of the installed unit before ordering.
Datasheets and compliance documents are available on request; quote the full catalog number when enquiring.
Common questions about UE43-4AR2D2
Q.Where can I find the mounting data for UE43-4AR2D2?
It is listed in the specification table for SICK UE43-4AR2D2 as DIN rail / panel. Check the revision of the installed unit if the catalog number has been superseded.
Q.For UE43-4AR2D2, what does the specification table state about enclosure rating?
The specification table lists enclosure rating = IP20 (IEC 60529) for SICK UE43-4AR2D2. Compare it with the nameplate of the installed unit before ordering.
Q.Which value is published under certifications for catalog number UE43-4AR2D2?
For UE43-4AR2D2, certifications is given as CE, cULus. Confirm this figure against the unit currently in the panel.
Q.What should I include in an enquiry for UE43-4AR2D2?
Send the full catalog number UE43-4AR2D2, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for SICK UE43-4AR2D2.
Q.How do I confirm compatibility of UE43-4AR2D2 before ordering?
Match the catalog number UE43-4AR2D2 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.