ProSoft Technology · PLX32 EtherNet/IP Gateway
PLX32-EIP-104 is a ProSoft Technology industrial component with Rated current Ie 300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC); Rated operational voltage 24 VDC nominal (10–36 VDC allowed); Supply voltage 24 V DC (IEC 61131-2). It is used in control panels, machine builds, spare-part replacements where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ie300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC)
-
Rated operational voltage24 VDC nominal (10–36 VDC allowed)
-
Supply voltage24 V DC (IEC 61131-2)
-
Enclosure ratingIP20 (IEC 60529)
Specifications
| Electrical |
| Rated current Ie |
300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC) |
| Rated operational voltage |
24 VDC nominal (10–36 VDC allowed) |
| Rated power kW |
7.2 W nominal (24 VDC @ 300 mA) |
| Supply voltage |
24 V DC (IEC 61131-2) |
| I/O and communication |
| Response time |
< 1 ms |
| Mechanical |
| Mounting |
DIN rail / panel |
| Enclosure rating |
IP20 (IEC 60529) |
| Environment and compliance |
| Operating temperature |
-25...+70 °C (IEC 60068-2-1) |
| Certifications |
CE, UL, cULus |
Values follow the ProSoft Technology PLX32 EtherNet/IP Gateway specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| ProSoft Technology PLX32 EtherNet/IP Gateway variants |
| Catalog number |
Rated current Ie |
Rated operational voltage |
Mounting |
|
PLX32-EIP-104 (this page) |
300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC) |
24 VDC nominal (10–36 VDC allowed) |
DIN rail / panel |
| PLX32-EIP-MBTCP |
300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC) |
24 VDC nominal (10–36 VDC allowed) |
DIN rail / panel |
| PLX32-EIP-PND |
300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC) |
24 VDC nominal (10–36 VDC allowed) |
DIN rail / panel |
| PLX32-EIP-SIE |
300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC) |
24 VDC nominal (10–36 VDC allowed) |
DIN rail / panel |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The PLX32-EIP-104 is the device-level element in a ProSoft Technology industrial component installation. It receives the field signals and control supply listed above — 24 V DC (IEC 61131-2) — and switches or conditions the load within the 300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in control panels, machine builds, spare-part replacements, where the unit is matched to the original catalog number and the enclosure provides DIN rail / panel support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Industrial PLX32-EIP-104
Industrial PLX32-EIP-104 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number PLX32-EIP-104; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Mounting: DIN rail / panel — Check this value against the nameplate of the installed unit before ordering.
- Rated current Ie: 300 mA @ 24 VDC nominal; 610 mA max (10–36 VDC) — Match it to the existing panel and upstream protection.
- Rated power kW: 7.2 W nominal (24 VDC @ 300 mA) — Record it with the other nameplate data when sourcing a replacement.
- Rated operational voltage: 24 VDC nominal (10–36 VDC allowed) — Confirm the revision of the installed unit before a like-for-like replacement.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about PLX32-EIP-104
Q.Where can I find the rated operational voltage data for PLX32-EIP-104?
It is listed in the specification table for Industrial PLX32-EIP-104 as 24 VDC nominal (10–36 VDC allowed). Confirm this figure against the unit currently in the panel.
Q.For PLX32-EIP-104, what does the specification table state about supply voltage?
The specification table lists supply voltage = 24 V DC (IEC 61131-2) for Industrial PLX32-EIP-104. Use the value as the reference when sourcing a current-production equivalent.
Q.Which value is published under rated power kW for catalog number PLX32-EIP-104?
For PLX32-EIP-104, rated power kW is given as 7.2 W nominal (24 VDC @ 300 mA). Check the revision of the installed unit if the catalog number has been superseded.
Q.How do I confirm compatibility of PLX32-EIP-104 before ordering?
Match the catalog number PLX32-EIP-104 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.
Q.Can the PLX32-EIP-104 replace the unit currently installed in my panel?
Compare catalog number PLX32-EIP-104 and the ratings above with the nameplate of the installed device. A current-production equivalent is selected by function and electrical rating, not by the label alone.