ProSoft Technology 5201-MNET-MCM Gateway

SKU: 5201-MNET-MCM
Regular price $827.33
Available
Condition
Free shipping over $500
100% secure payments
Industry leading quality

5201-MNET-MCM ProSoft ProLinx Modbus TCP to Modbus Master/Slave Gateway

The ProSoft Technology 5201-MNET-MCM is standalone DIN-rail mounted ProLinx 5200 series protocol gateway. It enables bidirectional data exchange between Modbus TCP/IP network and serial Modbus (Modbus RTU / ASCII) Master & Slave devices. It acts simultaneously as Modbus TCP Client/Server and Modbus RTU/ASCII Master/Slave, supporting multi-drop serial field networks. Technical data sourced directly from official ProSoft 5201-MNET-MCM datasheet & user manual. Supplied by SHLY-PLC, an independent industrial automation distributor; each unit undergoes visual inspection and functional testing before shipment for retrofit and spare replacement projects. Contact our team for compatibility verification.

Features

  • Order Code: 5201-MNET-MCM
  • Product Family: ProLinx 5200 Series DIN Rail Gateway
  • Primary Function: Modbus TCP/IP to Serial Modbus RTU/ASCII Master/Slave Gateway
  • Mounting: Standard 35mm DIN rail mounting
  • Ethernet Port: Modbus TCP/IP Client & Server, 10/100Mbps, built-in web configuration & FTP
  • Serial Port: Isolated RS422/RS485, Modbus RTU / ASCII, works as Master or Slave
  • Serial Master Capacity: Support up to 32 Modbus RTU/ASCII slave devices on multi-drop bus
  • Data Mapping: Flexible user-defined register mapping between TCP and serial Modbus data tables
  • Configuration: ProSoft Configuration Builder (PCB), web browser setup, online diagnostics
  • Diagnostics LED: Power, module status, Ethernet activity, serial communication and fault indicators
  • Power Supply: 24 VDC nominal (18 ~ 30 VDC range)
  • Certifications: cULus UL508, CE, RoHS compliant
  • Lifecycle: Discontinued OEM production, legacy spare part only
  • Typical Use: Bridge serial Modbus RTU sensors, meters, drives to Modbus TCP PLC/SCADA; brownfield site upgrade, legacy serial Modbus network integration

Specifications

Official Datasheet & User Manual Technical Parameters

Technical Specifications
Catalog Number 5201-MNET-MCM
Hardware Type DIN Rail Protocol Gateway, ProLinx 5200 Series
Supply Voltage 18 ~ 30 VDC, nominal 24VDC
Ethernet Interface Modbus TCP/IP Client / Server, 10/100Mbps
Serial Interface Isolated RS422/RS485, Modbus RTU / ASCII, Master or Slave selectable
Serial Bus Capacity Up to 32 serial Modbus slave nodes when running as serial master
Configuration Tool ProSoft Configuration Builder (PCB), Web-based configuration
Mounting 35mm DIN Rail
Environmental Ratings
Operating Temperature 0°C ~ +60°C (32°F ~ +140°F)
Storage Temperature -40°C ~ +85°C (-40°F ~ +185°F)
Relative Humidity 5% ~ 95% RH, Non-Condensing
Agency Certifications
cULus UL508
Compliance CE, RoHS

Compatibility & Cross-References

The 5201-MNET-MCM is ProLinx 5200 standalone gateway bridging Modbus TCP/IP and serial Modbus RTU/ASCII. It can operate serial port as either Master or Slave. Similar family:5201-MNET-MCP (Modbus TCP to Modbus Plus). This listing is provided by an independent industrial-automation distributor; brand names and part numbers are used for product identification only.

Applications

  • Connect serial Modbus RTU/ASCII transmitters, flow meters, drives to Modbus TCP PLC or SCADA system
  • Bi-directional register mapping between Ethernet Modbus and multi-drop RS485 serial Modbus network
  • Factory retrofit, convert legacy serial Modbus field equipment to Ethernet network
  • Spare replacement for existing ProLinx 5200 Modbus gateway installations

Warranty

  • Availability: 5201-MNET-MCM discontinued OEM production, supply as aftermarket spare; contact us for real-time stock status.
  • Inspection & testing: each unit is visually inspected and functionally checked before packing.
  • Delivery: orders are processed within 2-4 business days after payment confirmation; standard worldwide delivery is about 5-8 business days, express shipping available, orders over $500 ship free.

Warranty: 12-month seller warranty provided by SHLY-PLC. See our Return Policy for coverage and claims.

Independent supplier: ProSoft Technology part 5201-MNET-MCM is supplied by SHLY-PLC, an independent industrial automation distributor. Brand names and part numbers are used for product identification and remain the property of their respective owners; this listing is not affiliated with, sponsored or endorsed by the manufacturer.

Frequently Asked Questions

Q: What is 5201-MNET-MCM?

A: 5201-MNET-MCM is ProSoft ProLinx 5200 DIN rail gateway, converts Modbus TCP/IP to serial Modbus RTU/ASCII, serial port selectable as Master or Slave.

Q: How many serial Modbus slaves can it poll?

A: When configured as serial Modbus master, it supports up to 32 Modbus RTU/ASCII slave devices on RS485 multi-drop bus.

Q: What software is used for configuration?

A: ProSoft Configuration Builder (PCB), also supports web browser configuration and online bus diagnostics.

Q: What serial signals are supported?

A: Isolated RS422 / RS485 interface, works for Modbus RTU and Modbus ASCII protocols.

5201-MNET-MCM · Technical reference data · Independently supplied by SHLY-PLC

Standard International (tracked courier): delivered in 5–8 business days. In-stock items are processed within 2–4 business days. USD 25 flat rate on orders of $500 or less; free on orders over $500.

Express (DHL Express / FedEx International): upgraded expedited delivery in 2–4 business days. The Express surcharge is calculated at checkout based on destination and order weight.

Non-Stock / On-Order items ship on request: dispatch time is confirmed before your order — see our Shipping Policy. Remote-area and overweight surcharges, where applicable, are shown before checkout.

Every product is covered by a 12-month seller warranty provided by SHLY-PLC, effective from the date of delivery, against defects in materials and workmanship under normal use. Manufacturer or factory warranty service is not applicable, and extended warranty packages are not provided.

This warranty does not cover damage from misuse, improper installation, power surges, neglect, unauthorized repair, or normal wear and tear. See our Return Policy for warranty-claim instructions.

★★★★★

No reviews yet. Be the first to review this product!