Phoenix Contact · Safety relays
2700525 – PSR-MC32-3NO-1NC-24-230UC-SP · Safety relays
The Phoenix Contact 2700525 (PSR-MC32-3NO-1NC-24-230UC-SP) is a Safety relays in the Phoenix Contact range. The specification below is transcribed from the official Phoenix Contact product page for this order number, which publishes the technical data in 12 sections: Notes, Product properties, Electrical properties, Input data, Output data, Connection data and further sections.
Nominal voltage1 x LED (green)
Degree of protectionIP20
Ambient temperature-40 °C ... 55 °C (observe derating)
Dimensions22.5 mm
ConnectionPush-in connection
MaterialPA
How it works
Phoenix Contact keeps the values in the groups shown below, in the order the manufacturer publishes them: Notes, Product properties, Electrical properties, Input data, Output data, Connection data, Signaling, Dimensions, Material specifications, Characteristics, Environmental and real-life conditions, Mounting. The values are carried over unchanged from the official product page; nothing is added beyond what the manufacturer states for this order number.
Specifications
Notes
Note on application
Note on applicationOnly for industrial use
Product properties
Product typeSafety relays
Product familyPSRmini
ApplicationEmergency stop
ValueSafety door
ValueMagnetic switch
ValueTransponder
ValueLight grid
Control1 and 2 channel
Relay typeElectromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3
Insulation characteristics
Overvoltage categoryII, III (See the section “Insulation coordination”)
Degree of pollution2
Times
Typical response time< 150 ms (automatic start)
Value< 100 ms (manual, monitored start)
Typ. starting time with U s< 200 ms (when controlled via A1)
Response time< 200 ms (When requested via A1; applicative deactivation via A1/A2 is not permitted)
Typical release time< 20 ms (on demand via the sensor circuit)
Restart time< 1 s (Boot time)
Recovery time< 500 ms (following demand of the safety function)
Value100 ms (Availability time after activating the sensor circuit during manual start)
Start pulse lengthmin. 500 ms (manual start)
Electrical properties
Maximum power dissipation for nominal condition17.3 W (at I L ² = 72 A²)
Nominal operating mode100% operating factor
Rated insulation voltage250 V AC
Rated surge voltage/insulationSee data sheet, section “Insulation coordination”.
Supply
DesignationA1/A2
Rated control circuit supply voltage U S24 V AC/DC ... 230 V AC/DC -15 % / +10 %
Rated control supply current I Styp. 103 mA (24 V DC)
Valuetyp. 47 mA (48 V DC)
Valuetyp. 38 mA (110 V AC)
Valuetyp. 21 mA (230 V AC)
Power consumption at U S2.7 W (with DC)
Value2.9 W (with AC)
Apparent powertyp. 5 VA (at U S )
Inrush current< 80 A (Δt = 50 µs at U s )
Filter time2 ms (at A1 in the event of voltage dips at U s )
Protective circuit275 V varistor / 411 V suppressor diode
Input data
Digital: Sensor circuit (S10, S12, S13, S22)
Description of the inputsafety-related sensor inputs
ValueIEC 61131-2 Type 3 (S10, S12, S13) Current, inward (S10, S12, S13) Current, outward (S22)
Number of inputs4
Input voltage range "0" signal0 V DC ... 5 V DC (for safe Off; at S10/S12/S13)
Input voltage range "1" signal11 V DC ... 30 V DC (at S10/S12/S13)
Input current range "0" signal0 mA ... 2 mA (for safe Off; at S10/S12/S13)
Inrush current< 5 mA (typically with U S at S10/S12/S13)
Value> -5 mA (typ. with U S at S22)
Filter timemax. 1.5 ms (Test pulse width of low test pulses)
ValueTest pulse rate = 5 x Test pulse width
Concurrence∞
Max. permissible overall conductor resistance150 Ω
Protective circuitReverse polarity protection; 38.6 V suppressor diode
Current consumptiontyp. 4 mA (typically with U S at S10/S12/S13)
Valuetyp. -2 mA (typ. with U S at S22)
Digital: Start circuit (S34, S35)
Description of the inputnon-safety-related
Number of inputs2
Input voltage range "1" signal19.2 V DC ... 30 V DC
Inrush currenttyp. 10 mA (typ. with U S at S34/35, Δt = 330 ms)
Max. permissible overall conductor resistance150 Ω
Protective circuitReverse polarity protection; 38.6 V suppressor diode
Current consumptiontyp. 2.5 mA (typ. with U S at S34)
Valuetyp. 1 mA (typ. with U S at S35)
Output data
Relay: Enabling current paths (13/14, 23/24, 33/34)
Output description2 N/O contacts each in series, safety-related, floating
Number of outputs3
Contact switching type3 enabling current paths
Contact materialAgSnO 2
Switching voltagemin. 5 V AC/DC
Valuemax. 250 V AC/DC
Switching powermin. 50 mW
Inrush currentmin. 10 mA
Valuemax. 6 A
Switching capacity5 A (DC13)
Value5 A (AC15)
Limiting continuous current6 A
Sq. Total current72 A 2 (observe derating)
Switching frequencymax. 1 Hz
Mechanical service life10x 10 6 cycles
Output fuse6 A gL/gG
Value4 A gL/gG (for low-demand applications)
Relay: Signaling current path (41/42)
Output description2 N/C contacts parallel, non-safety-related, floating
Number of outputs1
Contact switching type1 signaling current path
Contact materialAgSnO 2
Switching voltagemin. 5 V AC/DC
Valuemax. 250 V AC/DC
Switching powermin. 50 mW
Inrush currentmin. 10 mA
Valuemax. 6 A
Limiting continuous current6 A
Switching frequency1 Hz
Mechanical service life10x 10 6 cycles
Output fuse6 A gL/gG
Value4 A gL/gG (for low-demand applications)
Connection data
Connection technology
pluggableyes
Conductor connection
Connection methodPush-in connection
Conductor cross-section rigid0.2 mm² ... 1.5 mm²
Conductor cross-section flexible0.2 mm² ... 1.5 mm²
Conductor cross-section, flexible, with ferrule, with plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section, flexible, with ferrule, without plastic sleeve0.25 mm² ... 1.5 mm² (only together with CRIMPFOX 6)
Conductor cross-section AWG24 ... 16
Stripping length8 mm
Signaling
Status display3 x LED (green)
Operating voltage display1 x LED (green)
Dimensions
Width22.5 mm
Height117.4 mm
Depth114.5 mm
Material specifications
Color (Housing)yellow (RAL 1018)
Housing materialPA
Characteristics
Safety data
Stop category (EN 60204-1)0
Safety data: EN ISO 13849
Performance level (PL)e
Safety data: IEC 61508 - High demand
Safety Integrity Level (SIL)3
Safety data: IEC 61508 - Low demand
Safety Integrity Level (SIL)3
Safety data: EN IEC 62061
Safety Integrity Level (SIL)3
Environmental and real-life conditions
Ambient conditions
Degree of protectionIP20
Min. degree of protection of inst. locationIP54
Ambient temperature (operation)-40 °C ... 55 °C (observe derating)
Value-40 °C ... 60 °C (mounted in the horizontal mounting position with ≥ 9 mm spacing)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m (Above sea level)
Max. permissible humidity (storage/transport)75 % (on average, 85% infrequently, non-condensing)
Max. permissible relative humidity (operation)75 % (on average, 85% infrequently, non-condensing)
Shock15g
Vibration (operation)10 Hz ... 150 Hz, 2g
Mounting
Mounting typeDIN rail mounting
Assembly noteSee derating curve
Mounting positionvertical or horizontal
Order number
2700525 — https://www.phoenixcontact.com/en-us/products/safety-relays-psr-mc32-3no-1nc-24-230uc-sp-2700525
Official source
Phoenix Contact official product page, technical data section (EN-US); order number 2700525.
FAQ
What voltage does the 2700525 operate at?
Phoenix Contact gives a nominal voltage of 24 V AC/DC ... 230 V AC/DC -15 % / +10 % for this order number.
What degree of protection does the 2700525 have?
It is rated IP20, as stated in the official technical data.
What ambient temperature is permitted?
Phoenix Contact specifies an ambient temperature of -40 °C ... 55 °C (observe derating).
What are the dimensions?
The technical data gives 22.5 mm.
How is the 2700525 connected?
Phoenix Contact specifies the connection as Push-in connection.
What material is the housing made of?
The technical data lists PA.
Shipping & support. Stock is held in Shanghai and dispatched worldwide with the manufacturer's documentation. Contact us for the current lead time, price and freight before ordering.