Phoenix Contact · Terminal Block
1853049 is a Phoenix Contact circuit breaker with Rated current Ie up to 41 A (IEC 60947-7-1); Tripping characteristic 7 mm; Rated operational voltage 800 V (IEC 60947-7-1). It is used in distribution boards, motor protection circuits, panel feeders where the installed unit is matched to the original catalog number and a compact, documented part is required.
-
Rated current Ieup to 41 A (IEC 60947-7-1)
-
Tripping characteristic7 mm
-
Rated operational voltage800 V (IEC 60947-7-1)
-
Breaking capacity Icu/Icshot-dip tin-plated
Specifications
| Electrical |
| Rated current Ie |
up to 41 A (IEC 60947-7-1) |
| Rated operational voltage |
800 V (IEC 60947-7-1) |
| Rated insulation voltage Ui |
250 V |
| Rated impulse withstand Uimp |
4.8 kV |
| Breaking capacity Icu/Ics |
hot-dip tin-plated |
| Tripping characteristic |
7 mm |
| Frequency |
2.21 kV |
| Rated torque |
0.5 Nm ... 0.6 Nm |
| Rated speed |
1 octave/min |
| Mechanical |
| Weight |
16.7 g |
| Mounting |
35 mm DIN rail (IEC 60715) |
| Terminal type |
Tin (5 µm - 7 µm Sn) |
| Terminal wire size |
0 ° |
| Environment and compliance |
| Operating temperature |
-40 °C ... 70 °C |
| Certifications |
CE, UL, cULus |
| Humidity |
30 % ... 70 % |
Values follow the Phoenix Contact Terminal Block specification for this catalog number; parameters not confirmed for this variant are omitted rather than estimated.
Model comparison in the same family
| Phoenix Contact Terminal Block variants |
| Catalog number |
Tripping characteristic |
Breaking capacity Icu/Ics |
Rated operational voltage |
|
1853049 (this page) |
7 mm |
hot-dip tin-plated |
800 V (IEC 60947-7-1) |
| 1853081 |
7 mm |
hot-dip tin-plated |
800 V (IEC 60947-7-1) |
| 1853094 |
7 mm |
hot-dip tin-plated |
800 V (IEC 60947-7-1) |
| 1851164 |
9 mm |
hot-dip tin-plated |
800 V (IEC 60947-7-1) |
Before selecting an alternative, confirm its dimensions, terminals and installation requirements in the manufacturer documentation.
Where it sits in the control system
The 1853049 is the device-level element in a Phoenix Contact circuit breaker installation. It receives the field signals and control supply listed above — 800 V (IEC 60947-7-1) — and switches or conditions the load within the up to 41 A (IEC 60947-7-1) ratings shown in the Specifications table. Wiring and protective devices are sized to those same numbers, not to a generic assumption.
Typical installations place it in distribution boards, motor protection circuits, panel feeders, where the unit is matched to the original catalog number and the enclosure provides 35 mm DIN rail (IEC 60715) support. Record the catalog number and revision from the nameplate of the installed unit before specifying a like-for-like spare.
Selection notes for Phoenix Contact 1853049
Phoenix Contact 1853049 — Industrial automation component supplied as a like-for-like replacement, selected by catalog number and published ratings. The figures below are taken from the specification table on this page for catalog number 1853049; confirm the installed unit's part number and revision so the replacement matches both electrically and mechanically.
- Tripping characteristic: 7 mm — Record it with the other nameplate data when sourcing a replacement.
- Weight: 16.7 g — Confirm the revision of the installed unit before a like-for-like replacement.
- Terminal wire size: 0 ° — Use it as the reference when cross-checking a current-production equivalent.
- Rated insulation voltage Ui: 250 V — Verify it in the project documentation before confirming the order.
Cross-check the ratings above with the installed device before confirming the order.
Common questions about 1853049
Q.For 1853049, what does the specification table state about breaking capacity Icu/Ics?
The specification table lists breaking capacity Icu/Ics = hot-dip tin-plated for Phoenix Contact 1853049. Confirm this figure against the unit currently in the panel.
Q.Which value is published under terminal wire size for catalog number 1853049?
For 1853049, terminal wire size is given as 0 °. Use the value as the reference when sourcing a current-production equivalent.
Q.Before ordering 1853049, which rated impulse withstand Uimp entry should be checked?
The rated impulse withstand Uimp entry quoted above is 4.8 kV. Check the revision of the installed unit if the catalog number has been superseded.
Q.What should I include in an enquiry for 1853049?
Send the full catalog number 1853049, the required quantity and a photo of the nameplate. Stock, lead time and the applicable compliance documents can then be confirmed for Phoenix Contact 1853049.
Q.How do I confirm compatibility of 1853049 before ordering?
Match the catalog number 1853049 and the specification values listed above against the installed unit, then confirm the firmware or hardware revision where a revision-sensitive part is involved.